The OXY-VENT Study

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorJeroen van Eijk

About this trial

Effective ventilation during cardiopulmonary resuscitation is essential but can be difficult to achieve consistently. Current practice relies on visible chest rise to guide ventilation volume, although this may not always accurately reflect the actual volume of air delivered. This study aims to determine whether a real-time ventilation feedback device, providing objective information on ventilation volume and air leakage, improves adherence to recommended ventilation volumes compared with standard ventilation without feedback. The study will focus on patients receiving CPR with a supraglottic airway and synchronous ventilation.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

None

Disqualifiers

None

Trial design

Design model

Parallel

Treatments tested in this trial

  • Ventilation Feedback Device (Active)

    Device

    The same flow sensor and device measure inspiratory and expiratory tidal volume, leakage, and ventilation timing, connected between the resuscitator bag and airway device. In feedback mode, the device displays real-time visual feedback to guide the provider toward a target expiratory tidal volume of 400-500 mL.

  • Control (Recording-Only)

    Device

    A ventilation feedback device integrated into standard resuscitation equipment, used during out-of-hospital cardiac arrest. The device measures inspiratory and expiratory tidal volume, leakage, and ventilation timing via a flow sensor connected between the resuscitator bag and airway device. In this arm, the device is randomly initiated in recording-only mode, recording the same ventilation parameters without displaying any feedback to the provider.

Treatment groups

515 Participants
are divided into 2 treatment groups
Group A: Feedback GroupExperimental treatment 1 intervention
Group B: Recording-Only (Control) GroupActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Proportion of guideline-adherent ventilation pauses per resuscitation attempt

A ventilation pause is a compression pause during CPR in which rescue breaths are delivered. Guideline adherence per pause is defined as delivery of two ventilations, each with a device-measured expiratory tidal volume of 400-500 mL, per European Resuscitation Council recommendations. For each patient, the proportion of guideline-adherent pauses is calculated as the number of adherent pauses divided by the total analyzable pauses during the resuscitation attempt. The primary outcome is the mean of this patient-level proportion, averaged across all patients, compared between feedback and control groups.

Time frame
From enrollment to the end of treatment at day 1

Secondary outcomes

1

Number of Participants with Prehospital Return of Spontaneous Circulation (ROSC)

Any return of spontaneous circulation (ROSC), defined per the Utstein Out-of-Hospital Cardiac Arrest Registry Template, at any point during the prehospital resuscitation attempt.

Time frame
From enrollment to the end of treatment at day 1
2

Number of Participants Surviving to 30 Days

Survival to 30 days

Time frame
From enrollment to day 30
3

Number of Participants with Favorable Neurological Outcome

Favorable neurological outcome, defined as a Modified Rankin Scale (mRS) score of 0-3, where 0 indicates no symptoms and 6 indicates death, assessed at hospital discharge or 30 days.

Time frame
From enrollment to hospital discharge or 30 days
4

Proportion of Guideline-Adherent Ventilations

Proportion (%) of ventilations with expiratory tidal volume 400-500 mL, per European Resuscitation Council recommendations, calculated across all ventilations pooled across patients during prehospital resuscitation. Device-recorded data, compared between feedback and control groups.

Time frame
From enrollment to the end of treatment at day 1

Other outcomes

1

Change in Ventilation Quality Over Time Within Resuscitation Attempts

Trend in the proportion (percentage-point change) of guideline-adherent ventilations across consecutive time intervals within a resuscitation attempt, pooled across patients. Device-recorded, compared between feedback and control groups.

Time frame
From enrollment to the end of treatment at day 1
2

EMS-Level Learning Curve in Ventilation Quality

Change in ventilation quality, expressed as percentage-point change in guideline adherence, at the EMS-provider level as a function of cumulative study exposure (number of cases performed). Device-recorded.

Time frame
Through study completion

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Jeroen van Eijk

Lead sponsor

Amsterdam UMC, location VUmc

Sponsor institution

Archeon Medical

Collaborator

This trial is not recruiting at the moment. You can still explore other options: