The Use of Contrast Enhanced Ultrasound (CEUS) In Post-Surgical Pancreatic Cancer Patients to Evaluate Local Disease Recurrence

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorThomas Jefferson University

About this trial

This pilot study is testing whether a special type of ultrasound called contrast-enhanced ultrasound (CEUS) can help detect if pancreatic cancer has come back after surgery.

People may be eligible to participate if they had surgery to remove pancreatic ductal adenocarcinoma (PDAC) from the head or body of the pancreas and are currently being monitored for cancer recurrence using CT scans.

The study plans to enroll 10 participants: 5 people whose cancer has returned and 5 people whose cancer has not returned, based on their standard medical imaging results. Participants will not be randomly assigned to groups.

Researchers will use a Logiq E10 ultrasound machine with CEUS technology to perform an ultrasound examination of the area where the surgery was performed. The goal is to determine whether CEUS can be a practical and useful tool for identifying local pancreatic cancer recurrence.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Be a patient that underwent surgical resection of PDAC located in the head or body of the pancreas and are being followed for recurrence with CT imaging as part of their standard of care.

Be 18 years of age or older.

If the subject is of child-bearing potential, must have a negative pregnancy test.

Be conscious and able to comply with study procedures.

Disqualifiers

Females who are pregnant or nursing.

Patients who have received an investigational drug in the 30 days before study drug administration or will receive one within 72 hours afterwards.

Patients on life support or in a critical care unit.

Patients with clinically unstable cardiopulmonary conditions (acute myocardial infarction, acute coronary artery syndromes, worsening or unstable congestive heart failure, or serious ventricular arrhythmias)

Trial design

Design model

Single group

Treatments tested in this trial

  • Lumason

    Drug

    Lumason will be administered as an intravenous bolus injection of up to 2.4 mL prior to CEUS imaging

  • Contrast-Enhanced Ultrasound

    Procedure/Surgery

    One transabdominal contrast-enhanced ultrasound examination of the pancreatic surgical site will be performed using a Logiq E10 scanner with a curvilinear (C1-6) probe following administration of Lumason.

Treatment groups

10 Participants
are divided into 1 treatment group
Group A: Contrast-Enhanced Ultrasound (CEUS)Experimental treatment 2 interventions

Trial outcomes

Primary outcomes

1

Presence of Contrast Enhancement in the Pancreatic Surgical Site on CEUS

CEUS image quality compared to standard ultrasound imaging as evaluated qualitatively by radiologists. This will be evaluated by presence of contrast enhancement in the surgical area that corresponds to viable tissue.

Time frame
At CEUS examination, up to 1 hour

Secondary outcomes

1

Size of Surgical Site Enhancement on CEUS

The surgical site area/volume with/without enhancement from CEUS

Time frame
approximately 1 hour
2

Size of Surgical Site Enhancement on CT Imaging

The surgical site area/volume with/without enhancement from CT imaging

Time frame
approximately 1 hour
3

Presence or Absence of Recurrence

Presence or absence of recurrence at the surgical site

Time frame
approximately 1 hour

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.