About this trial
The goal of this clinical trial is to evaluate the efficacy and safety of Medtronic 780G automated insulin delivery system in adult persons with type 1 diabetes and gastroparesis.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥18 years
Diagnosis of T1D for at least 12 months with stable insulin regimen for at least 2 months
HbA1c ≥8.0%
Diagnosis of gastroparesis per National Institute of Health (NIH) definition
Disqualifiers
Age <18 years
Current use of inhaled insulin (Afrezza)
Patients with T1D using any glucose lowering medications other than insulin at the time of screening
Pregnancy, breast feeding, or wanting to become pregnant
Trial design
Parallel
Treatments tested in this trial
Medtronic 780G AID
DeviceParticipants in Medtronic AID treatment group will use it for three months
Treatment groups
Trial outcomes
Primary outcomes
Time in Range (70-180 mg/dL)
Percentage of time that sensor glucose values are within the target range of 70-180 mg/dL, as measured by continuous glucose monitoring (CGM).
Secondary outcomes
HbA1c
Change in glycated hemoglobin (HbA1c) measured using standard laboratory methods.
Mean Sensor Glucose
Mean sensor glucose value derived from CGM data.
Time in Tight Target Range (70-140 mg/dL)
Percentage of time that sensor glucose values are between 70 and 140 mg/dL (TTIR), measured by CGM.
Time Above Range
Percentage of time that sensor glucose values are \>180 mg/dL and \>250 mg/dL, measured by CGM.
Other outcomes
Severe Hypoglycemia
Number of severe hypoglycemic events requiring assistance from another person.
Diabetic Ketoacidosis
Number of diabetic ketoacidosis events defined by standard clinical criteria.