About this trial
This study will compare the effectiveness of the TRADENT™ coronary scoring balloon with a conventional non-scoring balloon for lesion preparation in patients undergoing a drug-coated balloon (DCB)-first percutaneous coronary intervention (PCI) strategy for de novo coronary lesions. The study will evaluate angiographic acute gain after lesion preparation and assess whether improved lesion preparation leads to a higher rate of successful drug-coated balloon (DCB)-alone treatment. The study is a prospective, multicenter, randomized, open-label, blinded-endpoint trial.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥19 years and able to provide written informed consent.
Patients with stable coronary artery disease or non-ST-segment elevation acute coronary syndrome (NSTE-ACS) requiring percutaneous coronary intervention (PCI).
Patients for whom the operator has planned and documented a drug-coated balloon (DCB)-first strategy with the intention of achieving drug-coated balloon (DCB)-alone treatment of the index lesion before randomization. Drug-eluting stent (DES) may be used if lesion preparation is inadequate or required for patient safety.
Native coronary de novo lesion with visually estimated diameter stenosis (DS) ≥50% and ≤100%.
Disqualifiers
ST-segment elevation myocardial infarction (STEMI), cardiogenic shock, or ongoing hemodynamic instability within 72 hours before index percutaneous coronary intervention (PCI).
Unprotected left main coronary artery disease or saphenous vein graft lesion.
Substantial thrombus burden in the target lesion.
Balloon dilatation or other plaque-modification treatment of the target lesion before randomization.
Trial design
Parallel
Treatments tested in this trial
TRADENT Scoring Balloon
DeviceTRADENT™ coronary scoring balloon will be used for lesion preparation in de novo coronary lesions planned for a drug-coated balloon (DCB)-first strategy. The balloon will be selected at a 1:1 balloon-to-artery ratio based on the visually estimated reference vessel diameter and used for lesion preparation before definitive drug-coated balloon (DCB) or drug-eluting stent (DES) treatment. If the assigned balloon fails to cross the lesion, a smaller plain balloon may be used solely for crossing facilitation. The assigned TRADENT™ scoring balloon remains the designated lesion-preparation intervention.
Conventional Non-Scoring Coronary Balloon
DeviceA conventional non-scoring coronary balloon (compliant, semi-compliant, or non-compliant) will be used for lesion preparation in de novo coronary lesions planned for a Drug-Coated Balloon(DCB)-First Strategy. The balloon will be selected at a 1:1 balloon-to-artery ratio based on the visually estimated reference vessel diameter and used for lesion preparation before definitive Drug-Coated Balloon(DCB) or Drug-eluting stent (DES) treatment . If the assigned balloon fails to cross the lesion, a smaller plain balloon may be used solely for crossing facilitation.
Treatment groups
Trial outcomes
Primary outcomes
Acute Gain
Acute gain, defined as post-preparation Minimum Lumen Diameter minus baseline Minimum Lumen Diameter, measured by blinded Quantitative Coronary Angiography (QCA) core laboratory immediately after completion of lesion preparation with the assigned balloon (regardless of protocol-defined facilitation balloon use) and before final Drug-Coated Balloon/Drug-Eluting Stent treatment or rescue therapy. Unit: millimeters (mm).
Secondary outcomes
Percentage of Participants With Successful Lesion Preparation
Successful lesion preparation is a composite binary outcome assessed once per participant on the angiogram obtained immediately after lesion preparation with the assigned balloon. A participant is classified as successful if both of the following are met: (a) residual diameter stenosis is 30% or less and (b) Thrombolysis in Myocardial Infarction (TIMI) flow grade is 3. A participant who does not meet both is classified as not successful. The two assessments are not reported separately. The single reported value is the percentage of participants classified as successful.
Drug-Coated Balloon (DCB)-Alone Treatment Rate
Percentage of randomized participants achieving DCB-alone treatment of the target lesion. For each participant, two assessments at index percutaneous coronary intervention (PCI) are combined into one binary classification: (a) DCB treatment of the target lesion was completed and (b) no stent/scaffold was implanted in the target lesion. A participant is classified as DCB-alone only if both (a) and (b) are met. The two assessments are not reported separately. The single reported value is the percentage of participants classified as DCB-alone.
Bailout Stenting Rate
Percentage of participants with stent implantation for Thrombolysis in Myocardial Infarction (TIMI) flow ≤2, flow-limiting dissection, abrupt closure, excessive recoil, or other immediate safety need, before or after drug-coated balloon (DCB) treatment.
Severe Dissection After Lesion Preparation
Percentage of participants with National Heart, Lung, and Blood Institute (NHLBI) type C, D, E or F dissection on the angiogram after lesion preparation.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Ulsan University Hospital
Lead sponsor
KangWon National University Hospital
Collaborator
Korea University Guro Hospital
Collaborator
Hanyang University Seoul Hospital
Collaborator
Kosin University Gospel Hospital
Collaborator
Chonnam National University Hospital
Collaborator
Gyeongsang National University Changwon Hospital
Collaborator
This trial is not recruiting at the moment. You can still explore other options: