Transesophageal Echocardiography in Conductive System Pacing in Pediatric Patients

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age5-18
SponsorAssiut University

About this trial

* The investigatorse will use the guidance of Intraprocedural three-dimensional transesophageal echocardiography (3D-TEE) for Left Bundle Branch Area Pacing (LBBAP) lead implantation in pediatric patients. * This is expected to lead to more procedural efficiency, safe lead positioning and better electrical outcomes, also expected to decrease the lead related complications.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Pediatric patients aged <18years old.

Congenital complete atrioventricular block, atrioventricular block as a complication after heart surgery, and symptomatic bradycardia associated with channelopathies.

Indications for permanent pacemaker implantation followed contemporary guideline-based recommendations.

Pediatric patients had previous right ventricular lead implantation and deterioration of LV systolic function.

Disqualifiers

Patients will not attend for follow up after implantation.

Patients have critical systematic illness which may interfere with cardiac function assessment.

Patients have poor echocardiographic window.

General examination Systolic and diastolic blood pressure and heart rate assessment.

Trial design

Design model

Single group

Treatments tested in this trial

  • Left Bundle Branch Pacing

    Procedure/Surgery

    Implantation of permanent pacemaker either single or dual chamber under fluoroscopic guidance according the EHRA procedural recommendations with add value or 3D-TEE in the implantation procedure.

Treatment groups

56 Participants
are divided into 1 treatment group
Group A: Pediatric patients who are indicated for LBBAPOther 1 intervention

Trial outcomes

Primary outcomes

1

The percentage of success of LBBAP procedure with the guidance of intraprocedural 3D-TEE.

The investigators will reach the accurate site of the lead implantation in interventricular septum to pace the left bundle branch by the accurate imaging tool (intraprocedural 3D-TEE).

Time frame
half to one hour for each case implantation.

Secondary outcomes

1

The rate 'percent' of the lead related complications during follow up of the cases after implantation.

The participants follow up will be after one week and then after three months to detect the complications by the measurement tool (change in baseline programming pacing threshold in volt).

Time frame
one week to three months
2

Assessment of the lead site inside the interventricular septum for the rate 'percent' of lead displacement complications during follow up.

The measurement tool is transthoracic echocardiography for measurement the lead site in mm inside the interventricular septum and any change in shape of electrocardiogram waves.

Time frame
one week to three months

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: