TRI-SUCCESS - Tricuspid Regurgitation Study of the Unica™ Cross-Caval System for the Evaluation of Efficacy and Safety in Significant TR Subjects

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-85
SponsorInnoventric LTD

About this trial

Prospective, multi-center, randomized, open-label, controlled pivotal study to assess the safety and effectiveness of the Innoventric Unica™ heterotopic cross-caval stent with OMT compared to OMT alone in the treatment of severe or greater TR.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

18 ≤ Age ≤ 85

Clinically symptomatic severe or greater tricuspid regurgitation

Symptomatic (NYHA functional classification of II-IVa), despite OMT.

The subject is deemed unsuitable for tricuspid valve surgery, tricuspid transcatheter edge-to-edge repair (t-TEER), or orthotopic transcatheter tricuspid valve replacement (TTVR), as determined by a multidisciplinary Heart Team.

Disqualifiers

LVEF < 30%

Severe RV dysfunction

Anatomical suitability according to CT scan

Systolic Pulmonary Artery Pressure (measured per RHC) > 65mmHg or PVR >4 WU

Trial design

Design model

Parallel

Treatments tested in this trial

  • Innoventric Unica™ System

    Device

    The Unica™ heterotopic cross-caval transcatheter tricuspid valve replacement in conjunction with Optimal Medical Therapy

Treatment groups

510 Participants
are divided into 2 treatment groups
Group A: DeviceExperimental treatment 1 intervention
Group B: ControlNo intervention 0 interventions

Trial outcomes

Primary outcomes

1

Rate of Major Adverse Events (MAE)

Proportion of subjects experiencing a Major Adverse Event (MAE) in the device arm.

Time frame
30 Days
2

Reduction of at least one grade in Caval Reflux

Reduction of at least one grade in Caval Reflux assessed by the imaging core laboratory. The caval reflux will be assessed using the 3-grade scale * 1- no reflux, reflux extending for less than 1 cm below the diaphragm (RA-IVC junction) * 2- reflux extending for less than 3 cm from the diaphragm (RA-IVC junction) * 3- reflux of 3 cm or more from the diaphragm (RA-IVC junction).

Time frame
6 months
3

Hierarchical Composite Endpoint including: improvement in KCCQ overall score, improvement in NYHA classification, improvement in 6MWD

Hierarchical Composite Endpoint analyzed using win-ratio - comparison of the number of wins between device and control arms

Time frame
6 months
4

Hierarchical Composite Endpoint including: all-cause mortality, RVAD implant or heart transplant, HF hospitalizations (total number), TR (re-)intervention, change in KCCQ-12 overall score, change in NYHA classification, change in 6MWD

Hierarchical Composite Endpoint analyzed using win-ratio - comparison of the number of wins between device and control arms

Time frame
1 Year

Secondary outcomes

1

All-cause mortality

Time frame
1-year
2

Cardiovascular mortality

Time frame
1-year
3

Rate of HF hospitalizations

Time frame
1-year
4

Rate of HF hospitalizations combined with all-cause mortality

Time frame
1-year

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Innoventric LTD

Lead sponsor

Innoventric Inc.

Collaborator

This trial is not recruiting at the moment. You can still explore other options: