About this trial
This study aims to investigate the factors influencing adherence to pelvic floor muscle training (PFMT) devices among patients with pelvic floor dysfunction (PFD) through structured questionnaires, while simultaneously comparing the effectiveness of different feedback modalities, including non-invasive ultrasound imaging and invasive manometry with electromyography (EMG). By integrating subjective adherence data with objective performance outcomes, the project seeks to evaluate the potential of system-level integration for personalized therapeutic strategies, ultimately enhancing treatment efficacy, improving patient satisfaction, and promoting sustained engagement in PFMT.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Women aged 21 years or older diagnosed with pelvic floor muscle dysfunction and requiring pelvic floor muscle training (e.g., for symptomatic pelvic organ prolapse, stress urinary incontinence, or dysfunctional voiding).
A Pelvic Floor Disability Index (PFDI-20) score greater than 1.
Ability and willingness to provide written informed consent and authorization for the release of personal health information.
Willingness and ability to complete all required questionnaires
Disqualifiers
Individuals planning a future pregnancy.
Inability to read, understand, or sign the written consent form prior to participation.
Trial design
Crossover
Treatments tested in this trial
Ultrasound Biofeedback Device
DeviceApplication of trans-abdominal ultrasonography as a biofeedback tool during pelvic floor muscle training
Manometer Biofeedback Device
DeviceApplication of manometry as a biofeedback tool during pelvic floor muscle training. The manometer is a routinely used clinical device in hospital-based pelvic floor rehabilitation programs to provide quantitative intravaginal pressure feedback and guide patients in performing correct pelvic floor muscle contractions.
Treatment groups
Trial outcomes
Primary outcomes
Bladder base displacement (cm) during pelvic floor muscle contractions measured by transabdominal ultrasound
Transabdominal ultrasound imaging will be employed to provide real-time visualization and quantitative assessment of bladder base displacement during pelvic floor muscle (PFM) contractions. The displacement of the bladder base (in centimeters) will be recorded. Data will be aggregated as mean ± standard deviation.
Change in bladder base angle (degrees) relative to the horizontal line during pelvic floor muscle contractions measured by transabdominal ultrasound
Transabdominal ultrasound imaging will be used to quantify the angular change of the bladder base relative to a horizontal reference line during pelvic floor muscle (PFM) contractions. The angle (in degrees) at rest and during contraction will be recorded, and the difference will be calculated. Data will be summarized as mean ± standard deviation across participants for each session.
Survey on Willingness to Use Pelvic Floor Muscle Training Devices
A structured questionnaire designed to assess participants' willingness to use pelvic floor muscle training (PFMT) devices. The survey evaluates multiple domains, including both physical and psychological aspects, providing insights into patient adherence and acceptance of different pelvic floor muscle training (PFMT) assistive tools. The questionnaire is based on a 7-point Likert scale, ranging from 1 ("strongly disagree") to 7 ("strongly agree"). Higher scores indicate greater willingness, acceptance, and positive perception toward the use of pelvic floor muscle training devices.
Secondary outcomes
Surface Electromyography
Electromyographic signals of pelvic floor muscle contractions will be recorded using the wireless surface EMG system.
Vaginal manometry measurement
A pressure-sensing probe will be inserted vaginally to measure intravaginal pressure (expressed in cmH₂O) generated during pelvic floor muscle contractions.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.