UNITY-B A Prospective, Multicentric, Single-arm Study to Evaluate the Safety and Efficacy of the UNITY-B Biodegradable Balloon-Expandable Biliary Stent System in Subjects With Biliary Strictures

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorQualiMed Innovative Medizinprodukte GmbH

About this trial

STUDY TYPE: Feasibility study STUDY DESIGN: Prospective, multicenter, single-arm, open-label PRIMARY OBJECTIVE The primary objective is to assess safety of the UNITY Balloon-expandable Biodegradable Biliary Stent System SECONDARY OBJECTIVES Clinical /Technical /Procedural success, Quality of Life improvement, biodegradation rate

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Benign fibrotic distal bile duct obstruction

Duct occlusion caused by cholelithiasis

A benign fibrotic distal obstruction of the Common Bile Duct (CBD), demonstrated by presence of a stenosis on magnetic resonance cholangiopancreatography (MRCP) and/or ERCP with proximal ductal dilation and cholestatic liver enzymes levels

Ductal anastomotic strictures

Disqualifiers

Subject is unwilling to comply with the follow-up schedule

Life expectancy < 12 m,

Inability to pass a guidewire through stricture

Contra-indication for endoscopy or interventional radiology

Trial design

Design model

Single group

Treatments tested in this trial

  • Biliary Duct Stenting

    Device

    UNITY-B Balloon-expandable Biodegradable Biliary Stent deployment in obstructed biliary ducts.

Treatment groups

100 Participants
are divided into 1 treatment group
Group A: Study Device Treated GroupOther 1 intervention

Trial outcomes

Primary outcomes

1

Safety Complication Rate for the first 30days

Total number of all complications is calculated as aggregate for the duration 30 days (day zero till day30 after index procedure). Two-sided 95% confidence intervals is constructed using exact (Clopper-Pearson) method.

Time frame
30 days

Secondary outcomes

1

Efficacy Rates of Clinical Success

Endpoints are analysed descriptively. Qualitative parameters are described by their distribution (frequencies and %); quantitative parameters are described by their mean, (SD±), min.-max., related to subjects with assessable data. Clinical Success; Normal serum bilirubin level (SBL) within 14 days after intervention. Relief of jaundice and pruritus. SBL is assessed directly before procedure day and at day14. Difference between both dates is calculated. Presence and absence of pruritus and jaundice shall behave accordingly to SBL. Postulated achieving a 20% reduction of SBL within the first 14days. Presence and absence of pruritus and jaundice is assessed and recorded at both SBL control dates.

Time frame
365days
2

Efficacy Rates of Technical Success

Technical Success; Total number of completed stent deployment.

Time frame
365days