About this trial
This study compare the effectiveness of 2 rehabilitation programmes that use (1) MT with Bilateral TENS (Bi-TENS), (2) sham-MT with Bi-TENS (Bi-TENS), respectively, in addition to conventional rehabilitation of standardized upper limb training, in improving upper limb motor functions, activities of daily living, community integration, and quality of life in patients with stroke.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
have been diagnosed with ischemic brain injury or intracerebral hemorrhage by MRI or computed tomography within three weeks to 10 years after the first onset of stroke;
have volitional control of the non-paretic arm, and at least minimal antigravity movement in the shoulder of the paretic arm;
have at least 5 degrees in wrist extension of the paretic arm in the antigravity position
are able to score > 6 of 10 of abbreviated Mental Test;
Disqualifiers
Have any additional medical, cardiovascular and orthopedic condition that would hinder the proper assessment and treatment;
Use cardiac pacemakers;
Have receptive dysphasia;
Have a significant upper limb peripheral neuropathy (e.g., diabetic polyneuropathy);
Trial design
Parallel
Treatments tested in this trial
Bilateral Transcutaneous electrical nerve stimulation (Bi-TENS)
DeviceThe stimulator is a 120z Dual-Channel TENS Unit (ITO Physiotherapy \& Rehabilittaion, Co, Ltd, Tokyo, Japan). The TENS stimulation will be at 100 Hz, with 0.2 ms square pulses at an intensity of twice the sensory threshold (defined as the minimum intensity at which subject reported feeling a tingling sensation and below the motor threshold as indicated by the absence of muscle twitching, to provide sensory stimulation to both paretic and intact arms. Two pairs of disposable surface electrodes will be applied over the median nerve from the carpal tunnel to the flexor digitorum superficialis and the superficial radial nerve from the extensor pollicis longus to the extensor digitorum communis, with the cathode on the proximal site, and the anode on the distal site.
Mirror Therapy (MT)
BehavioralA customised angle-adjustable frame with a mirror board will be used. All subjects are instructed to perform 1. Elbow flexion and extension exercise 2. Forearm pronation and supination exercise 3. Wrist flexion and extension exercise 4. Wrist radial and ulnar deviation exercise 5. Fingers opposition exercise 6. Gripping exercise The subject will complete bilaterally upper limb exercises during the 30 minutes period. Intact arm will be placed in front of mirror, and paretic arm will be placed behind the mirror. Joints involved will be flexed and extended in full available range in sitting positon, in order to improve the active control of elbow joint, wrist joint and all fingers joint respectively. Participants will be encouraged to focus on the image of intact arm when performing upper limb exercises bilaterally.
sham-Mirror Therapy (sham-MT)
BehavioralA customised angle-adjustable frame with a mirror board will be used while the reflecting surface of the mirror was covered with paper. All subjects are instructed to perform 1. Elbow flexion and extension exercise 2. Forearm pronation and supination exercise 3. Wrist flexion and extension exercise 4. Wrist radial and ulnar deviation exercise 5. Fingers opposition exercise 6. Gripping exercise The subject will complete bilaterally upper limb exercises during the 30 minutes period. Intact arm will be placed in front of covered mirror, and paretic arm will be placed behind the covered mirror. Joints involved will be flexed and extended in full available range in sitting positon, in order to improve the active control of elbow joint, wrist joint and all fingers joint respectively.
Conventional Rehabilitation Program
BehavioralStandardized upper limb training
Treatment groups
Trial outcomes
Primary outcomes
Fugl-Meyer Assessment of Upper Extremity (FMA-UE) - baseline
The FMA-UE will be used to evaluate the severity of motor impairment in the paretic upper extremity. The performance of 33 tasks will be assessed using a three-point ordinal scale (0 to 2), with a maximum score of 66. The FMA-UE will assess voluntary movement, reflex activity, grasp, and coordination of the upper extremity, and has a high inter-rater reliability (r=0.99) in patients with stroke. A higher scale score indicates a less severe motor impairment.
Fugl-Meyer Assessment of Upper Extremity (FMA-UE) - midterm
The FMA-UE will be used to evaluate the severity of motor impairment in the paretic upper extremity. The performance of 33 tasks will be assessed using a three-point ordinal scale (0 to 2), with a maximum score of 66. The FMA-UE will assess voluntary movement, reflex activity, grasp, and coordination of the upper extremity, and has a high inter-rater reliability (r=0.99) in patients with stroke. A higher scale score indicates a less severe motor impairment.
Fugl-Meyer Assessment of Upper Extremity (FMA-UE) - post-training
The FMA-UE will be used to evaluate the severity of motor impairment in the paretic upper extremity. The performance of 33 tasks will be assessed using a three-point ordinal scale (0 to 2), with a maximum score of 66. The FMA-UE will assess voluntary movement, reflex activity, grasp, and coordination of the upper extremity, and has a high inter-rater reliability (r=0.99) in patients with stroke. A higher scale score indicates a less severe motor impairment.
Fugl-Meyer Assessment of Upper Extremity (FMA-UE) - followup
The FMA-UE will be used to evaluate the severity of motor impairment in the paretic upper extremity. The performance of 33 tasks will be assessed using a three-point ordinal scale (0 to 2), with a maximum score of 66. The FMA-UE will assess voluntary movement, reflex activity, grasp, and coordination of the upper extremity, and has a high inter-rater reliability (r=0.99) in patients with stroke. A higher scale score indicates a less severe motor impairment.
Secondary outcomes
Grip Strength - baseline
Grip strength of both the paretic and intact hands will be measured using the Jamar dynamometer (Sammons Preston Rolyan, Bolingbrook, IL, USA) with standardized positioning and instructions recommended by the American Society of Hand Therapist. All subjects will be required to squeeze the dynamometer as hard as possible for 5 s for three trials. The force generated (in kilograms) in all three trials will be recorded and averaged for data analysis. The measurement of grip strength with the dynamometer has a high test-retest reliability (r=0.88-0.93) and inter-rater reliability (r=0.99).
Grip Strength - midterm
Grip strength of both the paretic and intact hands will be measured using the Jamar dynamometer (Sammons Preston Rolyan, Bolingbrook, IL, USA) with standardized positioning and instructions recommended by the American Society of Hand Therapist. All subjects will be required to squeeze the dynamometer as hard as possible for 5 s for three trials. The force generated (in kilograms) in all three trials will be recorded and averaged for data analysis. The measurement of grip strength with the dynamometer has a high test-retest reliability (r=0.88-0.93) and inter-rater reliability (r=0.99).
Grip Strength - post-training
Grip strength of both the paretic and intact hands will be measured using the Jamar dynamometer (Sammons Preston Rolyan, Bolingbrook, IL, USA) with standardized positioning and instructions recommended by the American Society of Hand Therapist. All subjects will be required to squeeze the dynamometer as hard as possible for 5 s for three trials. The force generated (in kilograms) in all three trials will be recorded and averaged for data analysis. The measurement of grip strength with the dynamometer has a high test-retest reliability (r=0.88-0.93) and inter-rater reliability (r=0.99).
Grip Strength - followup
Grip strength of both the paretic and intact hands will be measured using the Jamar dynamometer (Sammons Preston Rolyan, Bolingbrook, IL, USA) with standardized positioning and instructions recommended by the American Society of Hand Therapist. All subjects will be required to squeeze the dynamometer as hard as possible for 5 s for three trials. The force generated (in kilograms) in all three trials will be recorded and averaged for data analysis. The measurement of grip strength with the dynamometer has a high test-retest reliability (r=0.88-0.93) and inter-rater reliability (r=0.99).
Sponsors and contacts
Click on the lead sponsor to view all of their trials.