About this trial
FTEXES (Functionalized TEXtiles for Electrical Stimulation) is a wearable platform based on sensorized garments (Smart Pants and Smart T-shirt) with integrated textile electrodes for surface electromyography (EMG) recording and functional electrical stimulation (FES). This single-center, open-label, non-randomized study evaluates the usability of the system in a controlled laboratory setting. Fifteen participants (5 healthy adults, 5 patients with neuromotor disability, 5 healthcare professionals) take part in a single 45-60 minute session including donning, system setup, calibration, functional tasks (gait for the lower limb; reaching and grasping for the upper limb), doffing and skin inspection. Comfort, skin tolerability, stimulation-related discomfort, perceived usability, satisfaction and acceptability are assessed with standardized questionnaires. The quality of EMG signals recorded with textile electrodes is evaluated as a secondary objective. The study has no therapeutic purpose for individual participants.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Healthy adults: age 18 years or older; no neuromotor disability; written informed consent.
Patients: age 18 years or older, or 12-17 years with parental/guardian consent and minor's assent; neuromotor disability compatible with the use of the FTEXES system; indication for FES confirmed by a physiatrist. Previous FES experience is not required.
Healthcare professionals: professional qualification consistent with study activities (physiotherapist or physiatrist).
Disqualifiers
Missing informed consent (for minors: missing parental/guardian consent and/or minor's assent).
Inability to understand study aims and procedures or to follow instructions.
Clinical, functional, cognitive, behavioral or skin conditions that make participation unsafe or inappropriate, in the investigator's judgment.
Skin lesions, abrasions, dermatitis, irritation, infection or other dermatological conditions in device contact areas.
Trial design
Parallel
Treatments tested in this trial
FTEXES wearable system
DeviceSensorized textile garments (Smart Pants for the lower limb, Smart T-shirt for the upper limb) with integrated textile electrodes, connected to a CE-marked FES stimulator (HASOMED RehaMove3) and a CE-marked surface EMG system (FreeEMG 1000). Single session of about 45-60 minutes: donning, setup, calibration, functional tasks (gait cycle or reaching/grasping), doffing and skin inspection.
Treatment groups
Trial outcomes
Primary outcomes
Perceived usability: System Usability Scale (SUS) score
SUS is a 10-item questionnaire scored from 0 to 100; higher scores indicate better perceived usability.
Wearable comfort: Comfort Rating Scale (CRS) score
Comfort of the textile garments and textile electrodes assessed with the Comfort Rating Scale (CRS); higher scores indicate greater discomfort.
Stimulation-related pain/discomfort (NRS/VAS 0-10)
Global and localized discomfort, perceived fatigue and pain associated with functional electrical stimulation, rated on a 0-10 numeric/visual analogue scale; 0 = none, 10 = worst imaginable.
Satisfaction with the assistive device: adapted QUEST 2.0
Satisfaction with the FTEXES system assessed with an adapted version of the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0); items scored 1-5, higher scores indicate greater satisfaction.
Secondary outcomes
Coherence score (0.0-1.0) of EMG signal quality: amplitude and frequency spectrum
Coherence score (0.0 if signal amplitude \<50% of amplitude with standard Ag/AgCl electrodes -1.0 = signal amplitude = 100% of amplitude with standard Ag/AgCl electrodes) of Amplitude and frequency spectrum (% coveragle of signal spectrum) of surface EMG signals recorded with the textile electrodes of the FTEXES garments.
FES artifact rejection in EMG signals
Effectiveness of rejection of functional electrical stimulation artifacts in surface EMG signals recorded during stimulation scored as number number of artifacts recorded as number of artifacts out of 10 test events.
Other outcomes
Skin tolerability: visual skin inspection
Presence of redness, pressure marks, abrasions or other skin reactions in device contact areas, assessed by visual inspection at the end of the session.
Number of participants with adverse events
Adverse events recorded during the session using the study adverse event form.
Donning and setup performance
Time to don/doff the garments and connect/configure the system, level of assistance required and number of non-critical procedural errors, assessed by observation.