About this trial
This clinical trial studies whether an artificial intelligence (AI) software tool called iSeg can be safely and effectively used during routine radiation treatment planning for patients with lung tumors. Typical radiation treatment planning involves physicians manually outlining the tumors to plan where the radiation therapy will be delivered. This process can be time consuming and may vary between physicians. iSeg uses AI to analyze computed tomography (CT) images and generate a proposed tumor outline that can then be reviewed and modified by the treating physician during radiation treatment planning which may help improve accuracy and provide more consistent results and better planning. iSeg may be safe and effective to use during radiation treatment planning for patients with lung tumors.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients with radiographic findings consistent with lung cancer or solitary or oligo-metastatic disease in the lung. Most patients will have primary non-small cell lung cancer. For primary lung cancers, we include lesions with ground glass opacities with a solid component of 50% or greater. Patients with solitary or oligo-metastatic disease in the lung may have any other histology or cancer type
Patients must have radiographically measurable or evaluable disease per Response Evaluation Criteria in Solid Tumors (RECIST) v.1.1
Patients must be age ≥ 18 years
Patients must exhibit an Eastern Cooperative Oncology Group (ECOG) performance status of 0-2
Disqualifiers
Patients who have had prior radiotherapy with radiation field overlap
For primary lung cancers, patients with ground glass opacities without a solid component will be excluded
For oligo-metastatic cancers, patients with oligo-persistent disease are excluded
Patients who have not recovered from adverse events confined to the thorax (i.e. pneumonitis, bronchial insufficiency, bronchial hemorrhage, esophagitis) due to prior anti-cancer therapy (i.e., have residual toxicities ≥ grade 2) with the exception of alopecia, skin toxicity, low blood counts (neutropenia, anemia, etc), or anatomically distinct toxicities (i.e. cystitis)
Trial design
Single group
Treatments tested in this trial
Artificial Intelligence-based Intervention
Other interventionUndergo AI-directed segmentation of the tumor
Best Practice
Other interventionUndergo standard of care radiation planning
Computed Tomography
Procedure/SurgeryUndergo CT and/or PET/CT
Positron Emission Tomography
Procedure/SurgeryUndergo PET/CT
Radiology, Treatment Planning
Other interventionUndergo physician segmentation of the tumor
Stereotactic Body Radiation Therapy
RadiationUndergo SBRT
Survey Administration
Other interventionAncillary studies
Treatment groups
Trial outcomes
Primary outcomes
Determination of lesion segmentation and accuracy
The Dice Similarity Coefficient (DSC) and the 95th percentile Hausdorff Distance (HD95) will be calculated for each gross tumor volume (GTV) lesion by comparing physician de novo contours (P) with artificial intelligence (AI) contours (A). A linear mixed-effects model will be used to estimate the mean DSC(P, A\*) across all lesions while adjusting for patient-level clustering. The model will produce an estimated marginal mean DSC, its 95% confidence interval, and the one-sided p-value for the pre-specified hypothesis test of whether the mean DSC exceeds a clinically acceptable threshold. HD95(P, A) will be summarized descriptively using means, medians, and interquartile ranges. Sensitivity analyses will be performed if DSC values deviate substantially from normality; in such cases, per-patient mean DSC values will be computed and tested against the 0.72 threshold using a one-sample t-test or Wilcoxon signed-rank test.
Overall contouring time
The primary workflow endpoint examines whether AI assistance reduces overall contouring time relative to de novo physician contouring. For each patient (and each lesion when distinct timing is recorded), the time required for physician de novo contouring (T\_P) and for physician review and modification of AI-generated contours (T\_\[A\^\* \]) will be compared. The primary analysis will use a paired t-test to estimate the mean absolute reduction in time and the corresponding percent reduction. If patients contribute multiple lesions with independently recorded times, a linear mixed-effects model with a patient-level random intercept will be used instead of a simple paired test. This model will estimate the mean difference in contouring time and the associated 95% confidence interval. Will test whether T\_P is greater than Atime, indicating a workflow efficiency gain attributable to AI guidance. Percent time reduction, defined as (T\_P- T\_(A\^\* )) / T\_P × 100%, will be summarized.
Secondary outcomes
Evaluation of internal target volume (ITV) generation
Will evaluate ITV generation to characterize AI performance in motion-inclusive target delineation and to assess the clinical utility of AI-assisted respiratory motion integration. Geometric agreement between physician-derived and AI-assisted ITVs will be assessed using DSC, HD95, centroid displacement, contour volume differences, and voxel-wise edit maps. These analyses will characterize systematic differences in motion envelope definition, identify regions most frequently modified by physicians, and evaluate the impact of respiratory motion on AI-assisted target delineation.
Comparison of physician evaluation of contours versus AI only contours
For GTV, secondary segmentation analyses will include comparisons of physician de novo contours versus AI-only contours (P versus \[vs\] A), AI-only contours versus physician-modified AI contours (A vs A\*), and physician de novo contours versus physician-modified AI contours (P vs A\*). These comparisons will quantify both the magnitude and direction of physician edits and assess the extent to which AI-assisted contours converge toward physician-derived reference contours. For each lesion, DSC and HD95 will be summarized using descriptive statistics, and paired analyses (paired t-tests, non-parametric alternatives or mixed-effects models) will be used to compare contour sets.
Time to progression (Local control)
Will be estimated using the Kaplan-Meier method and reported as the proportion of patients alive without radiographic evidence of recurrence at the treated lesion.
Local failure
Will be defined using standard institutional radiographic criteria.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Northwestern University
Lead sponsor
National Cancer Institute (NCI)
Collaborator
This trial is not recruiting at the moment. You can still explore other options: