About this trial
The goal of this clinical trial is to learn whether wearable devices can accurately monitor health changes in adults with heart failure with reduced ejection fraction (HFrEF) and iron deficiency. The study will also evaluate how and when intravenous (IV) iron improves exercise capacity, sleep, stress, and other health measures in this population. The main questions it aims to answer are:
How does IV iron affect exercise performance measured by cardiopulmonary exercise testing (CPET)? How accurate are lab-built wearable devices compared with standard CPET equipment? Can commercial wearable devices such as the Apple Watch and Oura Ring reliably monitor heart rate, oxygen levels, activity, sleep, and stress over time in people with HFrEF and iron deficiency?
Researchers will compare participants who receive IV iron at the start of the study with participants who receive IV iron after the final study visit to see how iron treatment changes exercise capacity and wearable device measurements.
Participants will:
* Wear an Apple Watch and Oura Ring for about 120 days during regular life * Complete 2 CPET tests approximately 90 days apart * Wear additional investigational lab-built monitoring devices during CPET visits * Complete brief weekly questionnaires and daily smartwatch electrocardiograms (ECGs) * Receive IV iron either at the first CPET visit or after the second CPET visit depending on study group assignment
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥ 18 years
English Speaking
Able to use smartphone
Patients followed at TGH Heart Function Clinic
Disqualifiers
Individuals with known hypersensitivities to the wearable devices or related technology used in the study.
Unable to meet eligibility for CPET
hypersensitivities to the wearable devices
Living with LVAD
Trial design
Parallel
Treatments tested in this trial
Monoferric Injectable Product
DrugA single dose of IV Monoferric is the only study intervention.
Apple Watch
DeviceAn apple watch will be given to each participant - with an iPhone
Oura Ring
DeviceAn Oura Ring will be given to each participant
Treatment groups
Trial outcomes
Primary outcomes
Effect of IV iron on exercise capacity - Change in pVO2
Peak oxygen consumption (pVO2) will be measured using gold-standard cardiopulmonary exercise testing (CPET). Change in exercise capacity will be quantified as the change in pVO2, reported in mL/kg/min, between the Day 30 and Day 120 CPET assessments in the intervention and control groups.
Accuracy of lab-built devices - Heart Rate
The degree of agreement between heart rate measured by the Franklin Research Lab-built devices and heart rate measured by the reference ECG/cardiac monitoring system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired heart rate measurements, reported in beats per minute (bpm), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.
Accuracy of lab-built devices - SpO2
The degree of agreement between peripheral oxygen saturation (SpO2) measured by the Franklin Research Lab-built devices and SpO2 measured by the reference pulse oximetry system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired SpO2 measurements, reported as percent oxygen saturation (%), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.
Accuracy of lab-built devices - Systolic Blood Pressure
The degree of agreement between systolic blood pressure measured by the Franklin Research Lab-built devices and systolic blood pressure measured by the reference blood pressure monitoring system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired systolic blood pressure measurements, reported in millimetres of mercury (mmHg), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.
Secondary outcomes
Comparing the Accuracy of Commercial and Lab-built Devices - Heart Rate
Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. First, Heart rate (bpm) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference heart rate measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.
Comparing the Accuracy of Commercial and Lab-built Devices - SpO2
Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. Second, oxygen saturation (Sp02; %) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference SpO2 measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.
Comparing the Accuracy of Commercial and Lab-built Devices - pVO2
Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. First, peak oxygen consumption (mL/kg/min; or VO2 Max) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference pVO2 measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.
Patient Reported Usability
Participants will rate the usability of commercial wearable devices and the study application using the system usability scale (SUS). The questionnaire will assess participants' experience using the devices, including ease of use and ability to incorporate the devices into daily activities. A total usability score will be calculated according to the SUS scoring method.
Other outcomes
Impact of Patient-level Factors on Wearable Devices
Skin pigmentation will be assessed using the Monk Skin Tone Scale, a 10-point visual scale ranging from lighter to darker skin tones. The association between Monk Skin Tone Scale score and device measurement accuracy will be evaluated for cardiovascular parameters obtained from commercial wearable devices and Franklin Research Lab-built devices in iron-deficient patients with HFrEF. Device accuracy will be assessed by comparing device-derived measurements with the corresponding reference measurements obtained during study assessments. Measurement error will be evaluated across Monk Skin Tone Scale values to determine whether device accuracy varies according to skin pigmentation in the intervention and control groups.
Ability of lab-built devices to estimate hemoglobin status and screening for iron deficiency
Determine the ability and accuracy of lab-built devices and tests to estimate hemoglobin status and detect iron deficiency or anemia. Hemoglobin concentration estimated using the lab-built device will be compared with hemoglobin concentration (g/L) measured using clinical laboratory testing. The lab-built devices use bioimpedance and optical spectroscopy-including short-wave infrared (SWIR) technologies-to detect independent spectral signatures of water and hemoglobin. Accuracy will be quantified as the difference between paired hemoglobin measurements.