Using Wearable Devices to Monitor and Assess the Effect of Intravenous Iron Therapy on Patients Who Are Iron Deficient and Have Heart Failure With Reduced Ejection Fraction.

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorUniversity Health Network, Toronto

About this trial

The goal of this clinical trial is to learn whether wearable devices can accurately monitor health changes in adults with heart failure with reduced ejection fraction (HFrEF) and iron deficiency. The study will also evaluate how and when intravenous (IV) iron improves exercise capacity, sleep, stress, and other health measures in this population. The main questions it aims to answer are:

How does IV iron affect exercise performance measured by cardiopulmonary exercise testing (CPET)? How accurate are lab-built wearable devices compared with standard CPET equipment? Can commercial wearable devices such as the Apple Watch and Oura Ring reliably monitor heart rate, oxygen levels, activity, sleep, and stress over time in people with HFrEF and iron deficiency?

Researchers will compare participants who receive IV iron at the start of the study with participants who receive IV iron after the final study visit to see how iron treatment changes exercise capacity and wearable device measurements.

Participants will:

* Wear an Apple Watch and Oura Ring for about 120 days during regular life * Complete 2 CPET tests approximately 90 days apart * Wear additional investigational lab-built monitoring devices during CPET visits * Complete brief weekly questionnaires and daily smartwatch electrocardiograms (ECGs) * Receive IV iron either at the first CPET visit or after the second CPET visit depending on study group assignment

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age ≥ 18 years

English Speaking

Able to use smartphone

Patients followed at TGH Heart Function Clinic

Disqualifiers

Individuals with known hypersensitivities to the wearable devices or related technology used in the study.

Unable to meet eligibility for CPET

hypersensitivities to the wearable devices

Living with LVAD

Trial design

Design model

Parallel

Treatments tested in this trial

  • Monoferric Injectable Product

    Drug

    A single dose of IV Monoferric is the only study intervention.

  • Apple Watch

    Device

    An apple watch will be given to each participant - with an iPhone

  • Oura Ring

    Device

    An Oura Ring will be given to each participant

Treatment groups

100 Participants
are divided into 2 treatment groups
Group A: Participants receive IV iron with first CPET.Experimental treatment 3 interventions
Group B: Participants don't receive IV iron until after second CPET.Other 2 interventions

Trial outcomes

Primary outcomes

1

Effect of IV iron on exercise capacity - Change in pVO2

Peak oxygen consumption (pVO2) will be measured using gold-standard cardiopulmonary exercise testing (CPET). Change in exercise capacity will be quantified as the change in pVO2, reported in mL/kg/min, between the Day 30 and Day 120 CPET assessments in the intervention and control groups.

Time frame
From intervention (Day 30) to offboarding (Day 120)
2

Accuracy of lab-built devices - Heart Rate

The degree of agreement between heart rate measured by the Franklin Research Lab-built devices and heart rate measured by the reference ECG/cardiac monitoring system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired heart rate measurements, reported in beats per minute (bpm), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.

Time frame
From baseline (Day 30) to offboarding (Day 120)
3

Accuracy of lab-built devices - SpO2

The degree of agreement between peripheral oxygen saturation (SpO2) measured by the Franklin Research Lab-built devices and SpO2 measured by the reference pulse oximetry system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired SpO2 measurements, reported as percent oxygen saturation (%), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.

Time frame
From baseline (Day 30) to offboarding (Day 120)
4

Accuracy of lab-built devices - Systolic Blood Pressure

The degree of agreement between systolic blood pressure measured by the Franklin Research Lab-built devices and systolic blood pressure measured by the reference blood pressure monitoring system used during CPET in both groups of iron deficient HFrEF patients. Agreement will be evaluated by comparing paired systolic blood pressure measurements, reported in millimetres of mercury (mmHg), obtained during the resting, unloaded warm-up, incremental exercise, and recovery phases of CPET.

Time frame
From baseline (Day 30) to offboarding (Day 120)

Secondary outcomes

1

Comparing the Accuracy of Commercial and Lab-built Devices - Heart Rate

Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. First, Heart rate (bpm) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference heart rate measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.

Time frame
From enrolment (Day 0) to offboarding (Day 120)
2

Comparing the Accuracy of Commercial and Lab-built Devices - SpO2

Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. Second, oxygen saturation (Sp02; %) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference SpO2 measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.

Time frame
From enrolment (Day 0) to offboarding (Day 120)
3

Comparing the Accuracy of Commercial and Lab-built Devices - pVO2

Assess the difference in accuracy between lab-built and commercial device measurements of key physiological metrics during CPET. First, peak oxygen consumption (mL/kg/min; or VO2 Max) measured by the Franklin Research Lab-built device, Apple Watch, and Oura Ring will be compared with the reference pVO2 measurement obtained during the CPET. Measurement error will be calculated for each device relative to the reference measurement, and differences in measurement error between the lab-built and commercial devices will be assessed.

Time frame
From enrolment (Day 0) to offboarding (Day 120)
4

Patient Reported Usability

Participants will rate the usability of commercial wearable devices and the study application using the system usability scale (SUS). The questionnaire will assess participants' experience using the devices, including ease of use and ability to incorporate the devices into daily activities. A total usability score will be calculated according to the SUS scoring method.

Time frame
From enrolment (Day 0) to offboarding (Day 120)

Other outcomes

1

Impact of Patient-level Factors on Wearable Devices

Skin pigmentation will be assessed using the Monk Skin Tone Scale, a 10-point visual scale ranging from lighter to darker skin tones. The association between Monk Skin Tone Scale score and device measurement accuracy will be evaluated for cardiovascular parameters obtained from commercial wearable devices and Franklin Research Lab-built devices in iron-deficient patients with HFrEF. Device accuracy will be assessed by comparing device-derived measurements with the corresponding reference measurements obtained during study assessments. Measurement error will be evaluated across Monk Skin Tone Scale values to determine whether device accuracy varies according to skin pigmentation in the intervention and control groups.

Time frame
From enrolment (Day 0) to offboarding (Day 30)
2

Ability of lab-built devices to estimate hemoglobin status and screening for iron deficiency

Determine the ability and accuracy of lab-built devices and tests to estimate hemoglobin status and detect iron deficiency or anemia. Hemoglobin concentration estimated using the lab-built device will be compared with hemoglobin concentration (g/L) measured using clinical laboratory testing. The lab-built devices use bioimpedance and optical spectroscopy-including short-wave infrared (SWIR) technologies-to detect independent spectral signatures of water and hemoglobin. Accuracy will be quantified as the difference between paired hemoglobin measurements.

Time frame
From enrolment (Day 0) to offboarding (Day 30)

Sponsors and contacts