About this trial
The purpose of this study is to investigate the functional performance of the RENASYS◊ DYNAFLOW Instillation Therapy System for wound management in adults with acute and chronic wounds. The main question is for clinicians to assess whether this device is completely unsuitable, neutral, or completely suitable for wound management using negative pressure wound therapy with instillation. Participants will have up to 3 dressings applied over their wound with saline administered via negative pressure for up to 9 days and participate in ongoing checkups by the study team.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients must provide their own written informed consent
Patient is at least 18 years old at time of consent
Patient is or will be admitted as an in-patient, able to attend all required study visits and willing to undergo NPWTi treatment
Patient must be able to follow instructions and in the opinion of the Investigator deemed capable of completing protocol requirements
Disqualifiers
Patient with target wound contraindicated to use of the product under investigation, ancillary products or their components per the RENASYS◊ DYNAFLOW Instillation Therapy System IFU
Highly exuding
Located in anatomical areas where maintaining a seal is problematic with tunnels or undermining that would prevent NPWT application
Severe, unmanageable peri-wound compromise
Trial design
Single group
Treatments tested in this trial
RENASYS◊ DYNAFLOW Instillation Therapy
DeviceNegative Pressure Wound Therapy with saline instillation and/or dwell
Treatment groups
Trial outcomes
Primary outcomes
Functional Performance of the RENASYS◊ DYNAFLOW Instillation Therapy System in an acute care setting
Functional performance is defined by a clinician-assessed questionnaire with a 1-10 numeric rating scale (completely unsuitable \[1\]; neutral \[5\]; completely suitable \[10\]) of the RENASYS◊ DYNAFLOW Instillation Therapy System that is collected at end of treatment after final dressing removal. A higher rating score indicates a better performance outcome for the device.
Secondary outcomes
Application time of the RENASYS◊ DYNAFLOW Instillation Therapy System in an acute care setting
Instillation application time is measured in minutes and seconds from completion of RENASYS◊ foam and transparent film application through to completion of instillation system priming (when saline is visibly present within the foam dressing). A shorter application time indicates better device performance.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: