About this trial
This is a prospective validation study, multicenter, open-label, single-arm study, evaluating the concordance between capillary microsampling (using the VAMS Mitra device) and venous sampling in patients undergoing CDK4/6 therapy.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Adult patients (≥ 18 years) with breast cancer.
Patients currently receiving ribociclib, abemaciclib, or palbociclib.
Patients capable of performing capillary sampling (with or without assistance).
Patient information and signing of informed consent.
Disqualifiers
Patients with altered mental status or psychiatric disorder that, in the opinion of the investigator, would preclude a valid patient informed consent.
Persons deprived of their liberty or under guardianship.
Trial design
Single group
Treatments tested in this trial
Capillary samples using the VAMS Mitra device
Other interventionFive blood samples will be collected at a single time point during treatment, in accordance with the routine TDM schedule (the treatment duration will remain as per the prescribed CDK4/6 regimen). * 4 capillary samples (using the VAMS Mitra device) including 2 samples collected by the study nurse then 2 samples collected by the patient. * 1 venous sample (5 mL heparinized tube).
Treatment groups
Trial outcomes
Primary outcomes
Measurement of the concordance between the drug concentrations obtained from capillary and venous sampling.
The primary objective of the study is therefore to validate the reliability of capillary sampling (using the VAMS Mitra device) as an alternative to venous sampling for TDM of CDK4/6 inhibitors (ribociclib, abemaciclib, or palbociclib) in breast cancer patients. The primary endpoint will be the concordance between drug concentrations obtained from venous and capillary samples, assessed through Bland-Altman analysis.
Secondary outcomes
Intra-patient's variability of the measurements from microsamplings
Reproducibility of capillary microsampling will be evaluated from the four replicate VAMS collections (two patient-collected, two nurse-collected). We will estimate within-patient variability as the coefficient of variation (CV %) across replicates and report duplicate %-difference.
Acceptability of the device, as assessed by a patient satisfaction questionnaire.
A satisfaction questionnaire for the use of VAMS-type microsampling device will be completed by the patient after the samples collection. Patient acceptability and usability of VAMS will be summarized descriptively with exploratory comparisons by age, sex, and collection setting (clinic vs home where applicable).