About this trial
This randomised controlled trial compares three supraglottic airway devices (laryngeal masks) in children with a body weight of 3-30 kg undergoing elective surgery under general anaesthesia: the SaCoVLM video laryngeal mask (UE Medical), which has an integrated camera allowing visual confirmation and adjustment of mask position, the LMA Supreme (Teleflex) and the Ambu AuraGain (Ambu). Children are randomly assigned in a 1:1:1 ratio to one of the three devices. The main question is whether the SaCoVLM provides a higher oropharyngeal leak pressure (a measure of how well the mask seals the airway) than the LMA Supreme and the Ambu AuraGain. Secondary questions include first-attempt insertion success, the need for repositioning or reinsertion of the mask during surgery and airway-related complications.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Paediatric patients scheduled for elective surgery under general anaesthesia with a supraglottic airway device
Body weight 3-30 kg (supraglottic airway device sizes 1-2.5)
Written informed consent of the parent or legal guardian
Disqualifiers
Body weight < 3 kg or > 30 kg
Anticipated difficult airway
History of difficult airway
Indication for airway management by a method other than a supraglottic airway device
Trial design
Parallel
Treatments tested in this trial
SaCoVLM video laryngeal mask
DeviceAirway management with the SaCoVLM video laryngeal mask (UE Medical, China), a second-generation supraglottic airway device with an integrated camera. The video display is used to visualise the laryngeal inlet and to verify and, if necessary, adjust the device position. Size per manufacturer weight-based recommendation; cuff pressure 40-60 cmH2O.
LMA Supreme
DeviceAirway management with the LMA Supreme (Teleflex, USA), a second-generation supraglottic airway device inserted using the standard blind technique. Size per manufacturer weight-based recommendation; cuff pressure 40-60 cmH2O.
Ambu AuraGain
DeviceAirway management with the Ambu AuraGain (Ambu A/S, Denmark), a second-generation supraglottic airway device inserted using the standard blind technique. Size per manufacturer weight-based recommendation; cuff pressure 40-60 cmH2O.
Treatment groups
Trial outcomes
Primary outcomes
Oropharyngeal leak pressure (OLP)
Airway pressure (cmH2O) at which the circuit manometer reading becomes stable, measured with the breathing circuit in manual mode, ventilation paused, fresh gas flow 10 L/min and the APL valve set to 50 cmH2O, after stable ventilation is achieved.
Secondary outcomes
First-attempt insertion success rate
Proportion of patients in whom the device is successfully inserted with adequate ventilation at the first attempt.
Need for device repositioning or reinsertion during surgery
Proportion of patients requiring repositioning, reinsertion of the device or other airway intervention after successful insertion.
Incidence of perioperative airway-related complications
Proportion of patients with at least one of: desaturation (SpO2 \< 92%), laryngospasm, bronchospasm, aspiration; each complication also reported separately.
Blood staining of the device on removal
Proportion of patients with visible blood on the device or in secretions after device removal.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Masarykova Nemocnice v Usti nad Labem, Krajska Zdravotni a.s.
Lead sponsor
Faculty of Health Studies, J. E. Purkyně University in Ústí nad Labem
Collaborator
Charles University, Czech Republic
Collaborator
This trial is not recruiting at the moment. You can still explore other options: