Wearable HRV Biofeedback for Stress in Dementia Caregivers

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorInstituto de Investigación Marqués de Valdecilla

About this trial

This study will evaluate whether a nurse-led heart rate variability (HRV) biofeedback programme supported by a low-cost wearable sensor reduces autonomic dysregulation and perceived stress in informal caregivers of people with dementia. Participants will be prospectively allocated, without randomization, at the day-care-centre level. Before enrolment, the six centres will be characterised according to centre size, estimated number of eligible caregivers and expected recruitment volume, and arranged into three approximately matched pairs. One centre in each pair will implement CARE-COHERENCE and the other will serve as a concurrent comparison centre under a pre-specified operational implementation plan. Follow-up will continue for 12 months.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Adult (18 years or older) self-identified informal, unpaid caregiver of an older person with a clinical diagnosis of dementia attending one of the participating day-care centers.

Providing an average of at least 28 hours of unpaid care per week for a minimum of 3 months.

Able to understand study procedures and provide written informed consent.

Able to use a smartphone and a simple wearable device, independently or with brief study support.

Disqualifiers

Persistent or clinically significant cardiac arrhythmia preventing reliable interbeat-interval analysis.

Pacemaker-dependent rhythm or another condition that, in the investigator's judgment, precludes valid heart rate variability assessment.

Current participation in formal heart rate variability biofeedback or structured resonance-frequency breathing training, or equivalent training within the previous 3 months.

Severe uncontrolled psychiatric illness or cognitive impairment precluding informed consent or meaningful participation.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Heart rate variability biofeedback

    Behavioral

    Nurse-delivered behavioral self-regulation training combining individualized resonance-frequency paced breathing with real-time HRV feedback from a low-cost wrist- or chest-worn sensor capable of recording interbeat intervals, paired with a compatible training application. Dose: four supervised sessions of approximately 60 minutes in weeks 1-4, delivered individually or in small groups, followed by supported home practice in weeks 5-8 (target 10 minutes twice daily, or at least 70 accumulated minutes per week), plus one booster contact at month 3. Training frequency is set per participant during an initial paced-breathing assessment across approximately 4.5-6.5 breaths per minute. A brief positive-emotion self-regulation strategy is included. The device model, firmware, and application version are prespecified before recruitment and held constant where possible. Adherence is derived from device and application logs and a participant practice log.

Treatment groups

100 Participants
are divided into 2 treatment groups
Group A: CARE-COHERENCE HRV biofeedback programExperimental treatment 1 intervention
Group B: Usual caregiver supportNo intervention 0 interventions

Trial outcomes

Primary outcomes

1

Change in resting RMSSD

Root mean square of successive differences (RMSSD) derived from a standardised resting interbeat-interval recording obtained with the study wearable sensor and processed according to a prespecified HRV analysis protocol. Higher values indicate greater vagally mediated heart rate variability.

Time frame
Baseline and 6 months

Secondary outcomes

1

Change in perceived stress (Perceived Stress Scale, PSS-10)

Perceived stress measured with the 10-item Perceived Stress Scale (PSS-10). Total score ranges from 0 to 40. Higher scores indicate greater perceived stress; a decrease indicates improvement. Analyzed as change from baseline and as the follow-up value adjusted for the baseline score. This is the key secondary outcome.

Time frame
Baseline, 8 weeks, 6 months and 12 months
2

Maintenance of resting RMSSD at 12 months

Root mean square of successive differences (RMSSD, in milliseconds) derived from a standardized resting interbeat-interval recording obtained with the study wearable sensor and processed with the prespecified HRV analysis pipeline. Higher values indicate greater vagally mediated heart rate variability. Assesses whether any intervention effect on the primary outcome is maintained six months after the primary endpoint.

Time frame
Baseline and 12 months
3

Change in caregiver burden (Zarit Burden Interview, ZBI-22)

Caregiver burden measured with the 22-item Zarit Burden Interview. Total score ranges from 0 to 88. Higher scores indicate greater burden; a decrease indicates improvement.

Time frame
Baseline, 8 weeks, 6 months and 12 months
4

Change in resting SDNN

Standard deviation of normal-to-normal interbeat intervals (SDNN, in milliseconds) from the same standardized resting recording used for the primary outcome. Higher values indicate greater overall heart rate variability.

Time frame
Baseline, 8 weeks, 6 months and 12 months

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.