WeFlow-EndoSeal™ Aorta Vascular Plug System for the Treatment of Stanford Type B Aortic Dissection

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-80
SponsorHangzhou Endonom Medtech Co., Ltd.

About this trial

The goal of this prospective, multicenter, randomized controlled clinical trial is to evaluate the safety and efficacy of the WeFlow-EndoSeal™ vAorta Vascular Plug System combined with thoracic endovascular aortic repair (TEVAR) in patients diagnosed with Stanford type B aortic dissection. The main questions it aims to answer are:

Does WeFlow-EndoSeal™ combined with TEVAR provide superior therapeutic efficacy versus standard TEVAR alone for Stanford type B aortic dissection? Does the combined intervention maintain a comparable safety profile relative to standard TEVAR alone? Researchers will compare the test arm (WeFlow-EndoSeal™ Aorta Vascular Plug System plus TEVAR) with the control arm (standard TEVAR alone), with subjects randomized at a 1:1 ratio, to see if the add-on device enhances treatment outcomes without elevating safety risks.

Participants will:

Be randomly assigned to either the test arm or the control arm with equal probability, free from subjective influence of investigators or participants Undergo the corresponding standardized endovascular procedure per their group allocation Complete protocol-specified clinical follow-ups and imaging assessments for efficacy and safety evaluation

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients aged 18 to 80 years old.

Patients are diagnosed with subacute or chronic Stanford Type B aortic dissection and are scheduled to undergo TEVAR.

Upon imaging evaluation, The the maximum diameter of the false lumen landing zone where the vascular plug is intended to be deployed shall be in the descending thoracic aorta is ≤ ■■ mm..

Patients have suitable access conditions evaluated by imaging, allowing the steerable catheter delivery systems to enter the false lumen via the iliac artery, infrarenal aorta, or at the level of the renal artery tear.

Disqualifiers

Presence of persistent malperfusion of visceral arterial branches caused by dissection.

■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■.

Infectious aortic disease, Takayasu's arteritis, Marfan syndrome (or other connective tissue diseases).

Acute systemic infection.

Trial design

Design model

Parallel

Treatments tested in this trial

  • WeFlow-EndoSeal™ Aorta Vascular Plug System

    Device

    WeFlow-EndoSeal™ Aorta Vascular Plug System

  • Thoracic Endovascular Aortic Repair(TEVAR)

    Procedure/Surgery

    Thoracic Endovascular Aortic Repair(TEVAR)

Treatment groups

256 Participants
are divided into 2 treatment groups
Group A: test groupExperimental treatment 2 interventions
Group B: control groupActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

The 12-month Clinical Success Rate

Time frame
12 months postoperatively
2

Incidence of freedom from major adverse events within 30 days postoperatively.

Freedom from all-cause death, aortic rupture, myocardial infarction, renal failure, respiratory failure, ischemic stroke, intestinal necrosis, severe lower extremity ischemia or necrosis, and paraplegia within 30 days postoperatively.

Time frame
30 days postoperatively

Secondary outcomes

1

Immediate Technical Success Rate in the Test Group

Immediate technical success is defined as successful delivery of the Aorta Vascular Plug to the intended position, accurate positioning and successful deployment, with the delivery sheath safely withdrawn outside the body, and no conversion to open surgery.

Time frame
Intraoperative
2

Thrombosis Status of the False Lumen in the Descending Thoracic Aorta

Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the thrombosis status of the false lumen in the descending thoracic aorta (no thrombosis / partial thrombosis / complete thrombosis).

Time frame
30 days, 6 months, 12 months, and 24-60 months postoperatively
3

Change in the Maximum Diameter of the Descending Thoracic Aorta

Compare the CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in the maximum diameter of the descending thoracic aorta.

Time frame
30 days, 6 months, 12 months, and 24-60 months postoperatively
4

Change in Volume in the Descending Thoracic Aorta

Compare CTA results obtained preoperatively and at 30 days, 6 months, 12 months, and 24-60 months postoperatively to assess the change in true lumen, false lumen and total volume above the celiac trunk in the descending thoracic aorta.

Time frame
30 days, 6 months, 12 months, and 24-60 months postoperatively

Other outcomes