About this trial
The Zenith® Fenestrated+ Endovascular Graft Clinical Study will assess the safety and effectiveness of the Zenith® Fenestrated+ Endovascular Graft (ZFEN+) in combination with the BeGraft Balloon-Expandable FEVAR Bridging Stent Graft System (BeGraft) and Unibody2 for the treatment of patients with aortic aneurysms involving one or more of the major visceral arteries.
Up to 130 additional subjects may be enrolled in Continued Access phase of the study
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Thoracoabdominal, pararenal or juxtarenal aortic aneurysm with a diameter ≥ 55 mm for males and ≥ 50 mm for females
Thoracoabdominal, pararenal or juxtarenal aortic aneurysm with a growth rate of ≥ 5 mm in 6 months
Thoracoabdominal, pararenal or juxtarenal aortic aneurysm with aortic diameter > 2x the normal aortic diameter or saccular aneurysm that warrants treatment in the opinion of the investigator
Disqualifiers
Age < 18 years
Life expectancy < 2 years
Pregnant, breast-feeding, or planning to become pregnant within 60 months
Inability or refusal to give informed consent by the patient or legally authorized representative
Trial design
Single group
Treatments tested in this trial
Zenith Fenestrated+ Endovascular Graft in combination with the BeGraft Balloon-Expandable FEVAR Bridging Stent Graft System and Unibody2
DeviceEndovascular aneurysm repair
Treatment groups
Trial outcomes
Primary outcomes
Composite measure of device technical success and procedural safety
Percent of patients with device technical success and freedom from procedural safety events in the following criteria: 1. Device technical success which includes delivery, deployment, and withdrawal of the device without the need for unanticipated corrective intervention), and 2. Freedom from the following procedural safety events: rupture, aneurysm-related mortality, permanent paraplegia, new onset renal failure requiring dialysis, bowel ischemia requiring surgery, and disabling stroke
Composite measure of freedom from aneurysm-related mortality and clinically significant reintervention
Percent of patients meeting the following criteria: 1. Freedom from aneurysm-related mortality (death from aneurysm rupture, death from any cause occurring within 30 days of procedure or secondary intervention or device or procedure related death) and 2. Freedom from clinically significant reintervention (including open surgery to restore blood flow or restore bodily function, any device related intervention requiring hospitalization, placement of an additional endovascular graft component(s), placement of a stent(s) as indicated for loss of or for having inadequate fixation, seal or patency)
Sponsors and contacts
Click on the lead sponsor to view all of their trials.