A Comparative Study of the Results of Dynamic and OPD Static Measurement of Pupil Diameter Before and After Cataract Surgery by Pupil Detectors

ConditionCataract
Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age50-90
SponsorShanghai Eye Disease Prevention and Treatment Center

About this trial

Age-related cataract remains the leading cause of blindness in developing countries. And, with the aging of the population in these countries, the number of cataract patients will continue to grow. With accurate biological measurements and the implantation of a suitable IOL, most cataract patients can achieve good distance vision after surgery. Studies have shown differences in pupil diameter and sensitivity in patients with different refractive states, with correlations to accommodation status as well as refractive error. The pupil is an important factor to be evaluated during the selection of an artificial lens (Intraocular lens, IOL), especially a functional IOL.

Among the various instruments used for preoperative cataract biological measurements, the light source is mostly a fixed parameter, and the static pupil diameter measurement by fixed illumination light source detection as an evaluation method is relatively rough. In this study, we are going to simulate different illumination states in daily life and set up two kinds of measurement instruments, namely, OPD and binocular pupil detector, so as to obtain more realistic research results and to explore the following: 1. The static and dynamic measurement of pupil diameter by people of different refractive states in different periods of preoperative and postoperative period. 2. Whether there is a difference between the static and dynamic pupil measurement results, 2. the change of pupil size under the stimulation of different light sources, and to compare the difference between the two detection methods, to provide objective pupil indexes for the more scientific selection of functional IOLs, to provide a basis for the selection of more accurate pupil measurement methods, to accurately screen the population of the use of functional IOLs, and to improve the patient's satisfaction after the operation.

Purpose of the study To simulate the difference between the preoperative and postoperative pupil diameters of cataract patients measured by static and dynamic methods under daily illumination, to select a more accurate pupil measurement method, and to make corrections for the evaluation of preoperative biometric indexes.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

None

Disqualifiers

None

Trial population

Sixty eyes of patients who were treated with lens ultrasonic emulsification combined with IOL implantation in our hospital were selected. According to the preoperative refractive status, they were divided into orthokeratology group (-0.5D\~+0.5D), myopia group less than -0.5D, hyperopia group more than +0.5D, 20 eyes in each group.

Trial design

Design model

Case-only

Time perspective

Other

Treatments tested in this trial

  • cataract surgery

    Procedure/Surgery

    Phaco+IOL implention

Treatment groups

60 Participants
are divided into 3 treatment groups
Group A: Orthokeratology group1 intervention
Group B: myopia group1 intervention
Group C: hyperopia group1 intervention

Trial outcomes

Primary outcomes

1

pupil size

pupil size before and after cataract surgery

Time frame
1 week, 1 month, 3 months

Secondary outcomes

Other outcomes

Locations

This trial has no locations.