A Prospective, Multicenter, Observational Study Evaluating Safety and Effectiveness of SAPIEN 3 Transcatheter Aortic Valve Replacement for Type-0 Bicuspid Aortic Valve Stenosis Patients in China

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age50+
SponsorChinese Academy of Medical Sciences, Fuwai Hospital

About this trial

In China, bicuspid aortic valve (BAV) represents a significantly high proportion of the transcatheter aortic valve replacement (TAVR) population. The application of TAVR in patients with BAV is challenging due to complex anatomy. To date, no prospective study has evaluated the Sapien 3 TAVR in patients with Type-0 BAV.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age ≥50 years, and after thorough physician-patient discussion and shared decision-making, willing to undergo or accept TAVR.

Type-0 bicuspid aortic valve anatomy confirmed by multi-detector computed tomography (MDCT).

The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits.

Adequate iliofemoral access and acceptable level of vessel calcification and tortuosity for safe device implant.

Disqualifiers

Challenging calcification based on physician's experience and discretion

Aortic valve is a congenital unicuspid valve, congenital Type-1 or Type-2 bicuspid valve, tricuspid or quadricuspid valve

Severe femoral, iliac or aortic atherosclerosis, calcification, coarctation, aneurysm or tortuosity, which prevents transfemoral TAVR

Need for open heart surgery (including severe aortic regurgitation, mitral regurgitation or stenosis, or tricuspid regurgitation, congenital heart disease, AF, complex coronary artery disease)

Trial population

severe symptomatic aortic valve stenosis (AS) patients with type-0 bicuspid anatomy

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Transcatheter Aortic Valve Replacement

    Device

    Transcatheter Aortic Valve Replacement for patients with Type-0 bicuspid aortic stenosis.

Treatment groups

170 Participants
are divided into 1 treatment group
Group A: patients with Type-0 bicuspid aortic stenosis1 intervention

Trial outcomes

Primary outcomes

1

The composite of all-cause mortality, stroke, or rehospitalization

The composite of all-cause mortality, stroke, or rehospitalization

Time frame
At 1 year after procedure

Secondary outcomes

1

The composite of all-cause mortality, stroke, or rehospitalization

The composite of all-cause mortality, stroke, or rehospitalization

Time frame
At 30 days after procedure
2

The composite of device success

The composite of device success at 30 days comprising the following: freedom from mortality, successful access, delivery of the device, and retrieval of the delivery system, correct positioning of a single prosthetic heart valve into the proper anatomical location, freedom from surgery or intervention related to the device or to a major vascular or access-related, or cardiac structural complication, intended performance of the valve (mean gradient \<20 mmHg, peak velocity \<3 m/s, and less than moderate aortic regurgitation), according to the VARC-3 definition

Time frame
At 30 days after procedure
3

Annular rupture

Annular rupture

Time frame
At discharge(assessed up to 30 days)
4

Paravalvular leakage

Paravalvular leakage

Time frame
At discharge (assessed up to 30 days) , 30 days, 1year