About this trial
The purpose of this study is to assess how safe VARIPULSE catheter system is for treatment of a heart rhythm disease called persistent atrial fibrillation (PsAF) in participants who are having a catheter ablation procedure (treat heart rhythm disease). This includes isolation of pulmonary vein and superior vena cava (heart veins; pulmonary vein isolation \[PVI\] and superior vena cava isolation \[SVCI\]), with or without another technique called posterior wall isolation (PWI). Also, to assess how safe it is for participants who are having a catheter ablation procedure and at the same time receiving another procedure called left atrial appendage occlusion (LAAO; to reduce stroke risk). Additionally, to assess how well VARIPULSE catheter system works over a long period of time for treatment of PsAF in participants undergoing catheter ablation for PVI, SVCI and SVCI+PWI.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Participant has been diagnosed with symptomatic persistent atrial fibrillation (PsAF), which is defined as continuous atrial fibrillation (AF) sustained beyond 7 days in duration and less than 365 days in duration, documented by: i. A physician's note documenting diagnosis of symptomatic PsAF, as defined above; and ii. Two electrocardiograms (ECGs) showing continuous AF, with electrocardiogram taken at least 7 days apart (electrocardiograms cannot be greater than (>) 365 days prior to enrollment); or iii. A 24-hour arrhythmia monitor documenting continuous AF within the last 365 days
Participant is aged 18 - 80 years at the time of informed consent
Participant is willing and capable of providing informed consent
Participant is able and willing to comply with all pre-, post- and follow-up testing and requirement
Disqualifiers
Participant has continuous AF > 365 days (longstanding persistent AF)
Participant has AF secondary to electrolyte imbalance, thyroid disease, or reversible or non-cardiac cause (for example, untreated documented obstructive sleep apnea, acute alcohol toxicity, etc.)
Participant has had previous surgical or catheter ablation for AF
Participant is known to require ablation outside the left atrium (LA), superior vena cava (SVC), and the cavotricuspid isthmus (CTI) region (for example, atrioventricular reentrant tachycardia, atrioventricular nodal reentry tachycardia, ventricular tachycardia and Wolff-Parkinson-White)
Trial design
Parallel
Treatments tested in this trial
VARIPULSE Catheter System
DevicePulsed field ablation by VARIPULSE Catheter System (VARIPULSE bi-directional catheter and TRUPULSE generator) will be used.
LAAO Device
DeviceLAAO procedures will be performed using commercially available LAAO devices in accordance with the device's instruction for use (IFU).
Treatment groups
Trial outcomes
Primary outcomes
Number of Participants with Early Onset Primary Adverse Events (PAEs)
PAEs include early onset AEs such as esophageal perforating complications, phrenic nerve paralysis (PNP; permanent), cardiac tamponade/perforation, pulmonary vein stenosis (PVS), death (device or procedure related), stroke/ cerebrovascular accident (CVA), major vascular access, complication/bleeding, thromboembolism, myocardial Infarction (MI), transient ischemic attack (TIA), pericarditis, pulmonary edema (respiratory insufficiency), heart block, and vagal nerve injury/ gastroparesis.
Freedom from Documented (Symptomatic and Asymptomatic) Atrial Tachyarrhythmia Episodes
Number of participants reporting freedom from documented (symptomatic and asymptomatic) atrial tachyarrhythmia (that is, atrial fibrillation or atrial tachycardia or atrial flutter \[AF, AT or AFL\] of unknown origin) episodes based on electrocardiographic data and freedom from acute procedural failure, repeat ablation failure, surgical treatment for AF/AT/AFL, non-study catheter (NSC) failure, antiarrhythmic drug (AAD) failure and any direct current (DC) cardioversion procedure.
Secondary outcomes
Freedom from Documented (Symptomatic and Asymptomatic) Atrial Tachyarrhythmia Episodes
Number of participants reporting freedom from documented (symptomatic and asymptomatic) atrial tachyarrhythmia (that is, AF, AT or AFL of unknown origin) episodes based on electrocardiographic and freedom from acute procedural failure, repeat ablation failure, surgical treatment for AF/AT/AFL, NSC failure, AAD failure and any DC cardioversion (DCCV) procedure.
Change From Baseline in Quality of life, As Measured by the Total Atrial Fibrillation Effect on Quality-of-Life (AFEQT) Score
The AFEQT uses a questionnaire to evaluate symptoms, daily activities and treatment concerns participants have related to atrial fibrillation. An overall AFEQT score ranges from 0 to 100. A score of 0 corresponds to complete disability (or responding "extremely" difficult to all questions answered), while a score of 100 corresponds to no disability (or responding "not at all" limited, difficult or bothersome to all questions answered). A positive change in score corresponds to improvement in AF symptoms.
Sponsors and contacts