About this trial
Peri-implant mucositis is an inflammatory condition affecting the soft tissues surrounding dental implants. Conventional non-surgical treatment is primarily based on mechanical removal of bacterial biofilm, although complete and sustained resolution of inflammation may not always be achieved.
This randomized controlled clinical trial aims to evaluate whether the use of diode laser therapy as an adjunct to conventional non-surgical mechanical treatment provides additional clinical and biological benefits in patients with peri-implant mucositis.
Participants will be randomly assigned to receive either conventional mechanical debridement alone or mechanical debridement combined with adjunctive diode laser therapy. Clinical outcomes, including bleeding on probing, plaque index, and probing depth, will be evaluated during a 12-month follow-up period. Biological changes will also be assessed through peri-implant crevicular fluid volume and matrix metalloproteinase-8 (MMP-8) levels.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older.
Diagnosis of peri-implant mucositis according to the criteria established by the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions.
Disqualifiers
Systemic diseases capable of altering the immune response.
Chronic use of non-steroidal anti-inflammatory drugs (NSAIDs).
Systemic antibiotic therapy during the previous 6 months.
Non-surgical peri-implant treatment during the previous 6 months.
Trial design
Parallel
Treatments tested in this trial
Conventional Non-Surgical Treatment
Procedure/SurgeryMechanical debridement of the peri-implant surface using Teflon curettes and an ultrasonic device equipped with a Teflon tip, followed by irrigation of the peri-implant sulcus with 0.12% chlorhexidine and 0.05% cetylpyridinium chloride. Participants will also receive individualized oral hygiene instructions based on the modified Bass technique and the use of interdental cleaning devices.
FOX III Diode Laser Therapy
DeviceAdjunctive diode laser therapy using a FOX III diode laser (A.R.C. Laser GmbH, Nürnberg, Germany) operating at a wavelength of 810 nm in pulsed mode with an output power of 1 W. High-intensity photothermal therapy will be delivered using a 300-µm optical fiber introduced into the peri-implant sulcus parallel to the longitudinal axis of the implant and moved in an apico-coronal direction while progressing mesiodistally around the sulcus for 30 seconds. Subsequently, low-intensity photothermal therapy will be applied using a 1-cm applicator placed in contact with the peri-implant margin for 30 seconds on the buccal and palatal/lingual surfaces.
Treatment groups
Trial outcomes
Primary outcomes
Change in Bleeding on Probing (BOP)
Bleeding on probing will be assessed at six sites per implant using the modified peri-implant index described by Mombelli. Probing will be performed with an approximate force of 0.25 N using a periodontal probe. Changes from baseline will be compared between the conventional non-surgical treatment group and the adjunctive diode laser group.
Secondary outcomes
Change in Probing Depth (PD)
Probing depth will be measured at six sites per implant and defined as the distance, in millimeters, between the peri-implant mucosal margin and the base of the peri-implant sulcus. Measurements will be performed with an approximate probing force of 0.25 N using a periodontal probe.
Change in Plaque Index (PI)
Plaque index will be assessed at six sites per implant according to the criteria described by Silness and Löe. Changes from baseline will be evaluated during follow-up.
Change in Peri-Implant Crevicular Fluid (PICF) Volume
Peri-implant crevicular fluid will be collected from the mesiobuccal region using Periopaper strips. PICF volume will be quantified using a Periotron 8010 and converted from arbitrary units to volume according to a previously established calibration curve.
Change in Matrix Metalloproteinase-8 (MMP-8) Levels
Total MMP-8 concentration in peri-implant crevicular fluid will be determined using a commercially available human MMP-8 ELISA kit. Absorbance will be measured at 450 nm, and MMP-8 concentrations will be calculated by interpolation from the standard curve.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: