Current refraction assessment in children is dependent on the Eye Care Specialist and lacks standardization. Essilor has developed new algorithm assisted subjective refraction software dedicated to children of 6-12 years old and suitable for use with Vision-S™ and Vision-R™ phoropters, in addition to existing software.
Two different versions of the software have been developed: the first incorporating only the steps needed to perform an entire subjective refraction process (vA), and the second, identical to the first but incorporating additional steps useful for managing the child's attention and cooperation (vB).
The software performance in terms of subjective refraction results will be compared to a conventional subjective refraction method performed with the Vision-R™700 phoropter in manual mode.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Age between 6 and 12 years
Subject able to recognize and name the letters of the Latin alphabet
Pupillary distance (PD) not less than 49mm
Distance refractive error for spherical equivalence (SE) within the range of [-6.00 to +6.00 D] maximum of the two absolute values RE and LE; Cyl ≤ 3.00 D
Disqualifiers
Vulnerability of the subject
Amblyopia
Strabismus
Any current or evolving pathology manifested in the eye or the appendages which might have an influence on vision, or interfere with refractive state
Trial design
Parallel
Treatments tested in this trial
Non-cycloplegic Objective refraction
DeviceObjective refraction will be measured using an auto-kerato-refractometer/aberrometer without cyclopegia
Non-cycloplegic conventional subjective refraction
DevicePerformed with Vision-R™
Non-cycloplegic subjective refraction (Kids refraction software vA with Vision-R™)
DevicePerformed with Vision-R™
Non-cycloplegic subjective refraction (Kids refraction software vA with Vision-S™)
DevicePerformed with Vision-S™
Non-cycloplegic subjective refraction (Kids refraction software vB with Vision-R™)
DevicePerformed with Vision-R™
Non-cycloplegic subjective refraction (Kids refraction software vB with Vision-S™)
DevicePerformed with Vision-S™
Cycloplegic subjective refraction (Kids refraction software vA with Vision-R™)
DevicePerformed with Vision-R™
Cycloplegic subjective refraction (Kids refraction software vA with Vision-S™)
DevicePerformed with Vision-S™
Cycloplegic Objective refraction
DeviceObjective refraction will be measured using an auto-kerato-refractometer/aberrometer with cyclopegia
Non-cycloplegic Retinoscopy
DevicePerformed with a retinoscope without cycloplegia
Cycloplegic retinoscopy
DevicePerformed with a retinoscope with cycloplegia
Treatment groups
Trial outcomes
Primary outcomes
Subjective Sphere (with Kids refraction software vA, with Vision-R™ and with Vision-S™)
The term "sphere" means that the correction for myopia or hyperopia is spherical, equal in all meridians of the eye. This indicates the amount of lens power, measured in diopters (D), prescribed to correct myopia or hyperopia.
Subjective Cylinder (with Kids refraction software vA, with Vision-R™ and with Vision-S™)
Indicates the amount of lens power for astigmatism, measured in diopters (D) and represents the difference in the greatest and weakest powers of the eye, usually separated by 90 degrees.
Subjective Axis (with Kids refraction software vA, with Vision-R™ and with Vision-S™)
Indicates the orientation of the Cylinder, measured in degrees (°)
Subjective Sphere (with Kids refraction software vB, with Vision-R™ and with Vision-S™)
The term "sphere" means that the correction for myopia or hyperopia is spherical, equal in all meridians of the eye. This indicates the amount of lens power, measured in diopters (D), prescribed to correct myopia or hyperopia.