Assessing the Effects of Hormones on Noninvasive Transcranial Stimulation

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-40
SponsorCarnegie Mellon University

About this trial

This study is investigating how two types of non-invasive brain stimulation, transcranial electrical stimulation (TES) and transcranial magnetic stimulation (TMS), affect brain activity, and whether combining them produces stronger or more consistent effects than either one used alone. The motivation for this comes from the observation that TMS, which is FDA-approved for treating depression, tends to work less well in postmenopausal women because lower estrogen levels reduce the brain's ability to respond to stimulation. The research team believes that pairing TMS with TES, which targets a different set of brain cells, may be able to overcome this hormonal barrier and make stimulation more effective. Participants will come into the lab for up to 24 visits over 8 months, beginning with an initial visit to establish the right stimulation settings, followed by a series of stimulation sessions in which brain activity is measured before and after receiving either TES, TMS, or both together. For female participants, sessions will be scheduled at specific points in the menstrual cycle to capture the natural monthly rise and fall of estrogen, while male participants will be scheduled on a comparable fixed interval as a comparison group. The insights gained from this study could directly inform the development of better, more reliable brain stimulation treatments for women with depression.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Age between 18 and 40 years old

Female subjects must have regular menstrual cycles (defined as a cycle that occurs at predictable intervals, typically between 24 and 38-days length) via self-report

Disqualifiers

Allergies to henna

Allergies to gel used for electrodes

History of seizures or epilepsy

Subjects must not have any serious disease, disorder, infection, or cognitive impairments that could affect their ability to participate in this study.

Trial design

Design model

Crossover

Treatments tested in this trial

  • Transcranial Electrical Stimulation

    Device

    SharpFocus transcranial electrical stimulation (TES) uses a multichannel stimulator connected to a scalp electrode to deliver precisely timed, intensity-modulated electrical pulses. By varying the timing, amplitude, and location of these pulses, the system achieves focal stimulation of targeted cortical regions. Investigators will use Digitimer DS8R and/or Digitimer DS5 current stimulators to apply all current stimuli. These stimulators are CE certified and are intended for use in human research applications. The stimulator safely delivers brief duration (50-2000µs) current pulses for transcranial electrical stimulation and activation of nerves and muscles via surface electrodes. The current output of the DS8R is adjustable over the range 0mA to 1000mA, with a compliance voltage of up to 400V and an energy limit of 300mJ.

  • Transcranial Magnetic Stimulation

    Device

    Transcranial magnetic stimulation (TMS) uses an electromagnetic coil placed over the scalp to deliver precisely timed magnetic pulses that induce electric fields in targeted cortical regions. By varying the frequency, intensity, and coil position, the system achieves non-invasive stimulation of specific brain areas. Investigators will use the DuoMag XT-100 rTMS system manufactured by DEYMED Diagnostic. The device is a CE-certified Class IIa medical device intended for use in human research and clinical applications. The DuoMag XT-100 delivers both monophasic and biphasic pulses with a total pulse duration of 290 µs and a maximum discharge energy of 265 J, capable of stimulating at 100% intensity at 22 Hz and up to 100 Hz at less than 50% intensity.

  • TES + TMS

    Device

    The combined TMS+TES intervention delivers concurrent transcranial magnetic and electrical stimulation using the DuoMag XT-100 rTMS system and the Digitimer DS8R/DS5 current stimulators simultaneously. The DuoMag XT-100 is a CE-certified Class IIa device manufactured by DEYMED Diagnostic, delivering monophasic and biphasic pulses with a 290 µs pulse duration and 265 J maximum discharge energy, capable of 100% intensity at 22 Hz and up to 100 Hz at less than 50% intensity. The Digitimer DS8R/DS5 are CE-certified stimulators delivering brief duration (50-2000 µs) current pulses via surface electrodes, with current output adjustable from 0mA to 1000mA, compliance voltage up to 400V, and energy limit of 300mJ. Standard adhesive electrodes are replaced with Soterix Sintered Ag/AgCl ring electrodes featuring radial slits to impede induced eddy currents. Magnetic pulses are delivered via the DuoMag 70BF liquid-cooled butterfly coil. Pulses are interleaved with a 1-3 ms latency.

Treatment groups

25 Participants
are divided into 3 treatment groups
Group A: TES + TMSExperimental treatment 1 intervention
Group B: TESExperimental treatment 1 intervention
Group C: TMSExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Motor Evoked Potential Amplitude Change

Motor evoked potential (MEP) amplitude is recorded via surface EMG electrodes placed on the upper or lower limb musculature in response to single-pulse diagnostic TMS delivered to the primary motor cortex (M1). MEP amplitude is measured as the peak-to-peak voltage of the evoked muscle response in millivolts. The primary outcome is the change in trial-averaged MEP amplitude from before to after a train of up to 2,000 pulses of TMS, TES, or combined TMS+TES. This delta is compared across two hormonal phases of the menstrual cycle - estrogen nadir (days 1-3) and the late follicular phase (days 10-14) - and across the three intervention arms. A larger positive delta indicates greater corticospinal excitability / synpatic potentiation following stimulation, while a negative delta indicates suppression of corticospinal excitability / synpatic potentiation.

Time frame
MEP recorded at the same time as the diagnostic TMS pre-intervention and post-intervention of the 2,000 pulse stimulation at every session for at most 8 months / 24 sessions. Delta/change assessed after each session.

Secondary outcomes

1

Numerical Rating Scale

A numerical rating scale (NRS) uses numbers to quantify subjective experiences of pain. NRS scores will be self-reported on a scale of 0-10 with 0 being no pain and 10 being worst pain imaginable. NRS will be presented to patients during calibration phases of Transcranial Electrical Stimulation (TES), during heat pain thresholding, and during pressure pain thresholding in the form of a visual scale and be asked to vocalize a number between 0 and 10 in response to a pain stimulus.

Time frame
Recorded at the same time as 2,000 pulses of stimulation (intraprocedurally) at every session after a block of "N" stim pulses for at most 8 months / 24 sessions. The number of stim pulses vary by intervention arm.
2

Menstrual Phase Identification Questionnaire

The Menstrual Phase Identification Questionnaire (MPIQ) is a short self-reported survey used to identify the current stage of the participant's menstrual cycle. It is administered at baseline and periodically throughout the study, including at home via Qualtrics up to once per day when necessary, to confirm whether the participant is at estrogen nadir (days 1-3) or in the late follicular phase (days 10-14) prior to each stimulation session. This measure is used to verify accurate scheduling of stimulation sessions relative to hormonal phase and to serve as a proxy for circulating estrogen levels, which are expected to be low at estrogen nadir and elevated during the late follicular phase. Accurate phase identification is critical to the study design as the primary outcome measure - change in MEP amplitude - is compared across these two hormonal phases.

Time frame
At most daily from enrollment to the end of intervention period (up to 8 months). Will be recorded online at an unspecified time during the experimental period depending on the participants preference.
3

Paired Pulse Responses

Paired-pulse EMG responses are recorded via surface EMG electrodes placed on the upper or lower limb musculature in response to paired-pulse diagnostic TMS delivered to the primary motor cortex (M1). Three paired-pulse paradigms are employed: Short-Interval Intracortical Inhibition (SICI), measured at an interstimulus interval (ISI) of 1-5 ms, which reflects GABAergic inhibitory interneuron activity and is expressed as a reduction in MEP amplitude relative to an unconditioned test stimulus; Intracortical Facilitation (ICF), measured at an ISI of 7-20 ms, which reflects glutamatergic excitatory interneuron activity and is expressed as an increase in MEP amplitude relative to an unconditioned test stimulus; and Long-Interval Intracortical Inhibition (LICI), measured at an ISI of 100-200 ms, which reflects GABA-B mediated inhibition and is expressed as a reduction in MEP amplitude relative to an unconditioned test stimulus. The outcome is the change in each of measure from baseline.

Time frame
Immediately prior to intervention/Immediately post-intervention at every session for at most 24 sessions/8 months
4

EMG responses

In addition to peak-to-peak MEP amplitude and paired-pulse responses, a range of additional quantitative metrics derived from the surface EMG signal are recorded before and after each repetitive stimulation train. These include but are not limited to MEP latency, MEP duration, MEP waveform morphology, and trial-to-trial variability of evoked responses. EMG is recorded via HD-EMG grids and/or bipolar electrode configurations placed on the upper and lower limbs, capturing muscle activity evoked by single-pulse diagnostic TMS delivered to the primary motor cortex (M1). These measures provide supplementary characterization of corticospinal excitability and neuromuscular response properties beyond MEP amplitude alone, and are compared across hormonal phases and intervention arms to gain a broader understanding of how repetitive TMS, TES, and combined TMS+TES modulate cortical output.

Time frame
Recorded at the same time as 2,000 pulses of stimulation (intraprocedurally) at every session for at most 8 months / 24 sessions.

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: