Automated Versus Manual Oxygen Titration With the EMILY.AI Device in Hospitalized Patients With Acute Respiratory Failure

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorAether Tech S.L.

About this trial

This randomized study evaluates EMILY.AI, an investigational (non-CE-marked) smart oxygen valve that automatically adjusts the oxygen flow delivered to a patient.

Adults admitted to the pulmonology ward of Hospital Universitario Fundación Jiménez Díaz (Madrid, Spain) with acute respiratory failure are randomly assigned to receive oxygen titrated automatically by EMILY.AI or oxygen managed as usual by the nursing team, from randomization until hospital discharge. All participants wear the device; in the usual-care group it only records data.

The study compares the time patients stay within their target saturation range, episodes of low and high oxygen, nursing workload, oxygen use, length of stay and patient experience. This substudy is part of clinical investigation FJD-EMILY-23-02, whose other substudies are registered in separate records.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Men and women aged 18 years or older.

Admitted to the general pulmonology ward (Unit 67) of Hospital Universitario Fundación Jiménez Díaz.

Acute respiratory failure, defined as baseline arterial PaO2 below 60 mmHg or the need for supplemental oxygen to maintain SpO2 above 90%. Patients on long-term oxygen therapy are eligible if a clinical deterioration requires a higher-than-usual oxygen flow to maintain SpO2 above 90%.

Signed informed consent.

Disqualifiers

Anatomical abnormalities preventing correct placement of the pulse oximeter.

Pregnancy or breastfeeding (women of childbearing potential require a negative pregnancy test at screening).

Need for non-invasive ventilation or high-flow nasal cannula at admission.

Palliative care or limitation of therapeutic effort at admission.

Trial design

Design model

Parallel

Treatments tested in this trial

  • EMILY.AI closed-loop oxygen titration

    Device

    Investigational smart oxygen valve with rule-based algorithm that adjusts oxygen flow to keep SpO2 within a target range.

  • Manual oxygen titration

    Other intervention

    Usual care: oxygen flow set and adjusted by the ward nursing team according to standard practice. The EMILY.AI device stays connected in fixed mode, recording signals but not controlling delivery.

Treatment groups

100 Participants
are divided into 2 treatment groups
Group A: EMILYExperimental treatment 1 intervention
Group B: MANUALActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

EFFICACY - EVALUATION OF THE RATE THE DEVICE MAINTAINS BLOOD OXYGEN SATURATION LEVELS

Percentage of monitored time with SpO2, measured by pulse oximetry, within the predefined target range (hypoxemic patients 94-98%; hypercapnic patients 92-94%), without delivering less or more oxygen than required. Comparing the closed-loop period (EMILY.AI) and the manual titration period.

Time frame
From randomization to hospital discharge, up to 30 days.

Secondary outcomes

1

ACCURACY - MEASUREMENT OF THE SYSTEM'S ACTION SPEED CORRECTING THE OXYGEN SATURATION

Time in seconds from 1) detection of SpO2 outside the target range to the start of correction and 2) the return to the target range.

Time frame
From randomization to hospital discharge, up to 30 days.
2

SAFETY - TIME WITH OXYGEN SATURATION BELOW AND ABOVE THE TARGET RANGE

Percentage of monitored time with SpO2 below and above the target range, as indicators of insufficient or excess in oxygen delivery. Comparing the closed-loop period (EMILY.AI) and the manual titration period.

Time frame
From randomization to hospital discharge, up to 30 days.
3

EFFICIENCY - MEASUREMENT OF THE NUMBER OF TIMES THE MEDICAL AND NURSING TEAM MUST ADJUST OXYGENATION

Number of nursing or medical interventions to adjust oxygen flow or address oxygenation-related symptoms. Comparing the closed-loop period (EMILY.AI) and the manual titration period.

Time frame
From randomization to hospital discharge, up to 30 days.
4

EFFICIENCY - OXYGEN FLOW DELIVERED

Mean delivered oxygen flow (L/min), distinguishing flow delivered while SpO2 was above the target range, comparing the closed-loop period (EMILY.AI) and the manual titration period.

Time frame
From randomization to hospital discharge, up to 30 days.

Other outcomes