BIO|STREAM.CSP Study

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorBiotronik SE & Co. KG

About this trial

The registry is designed to assess outcome, performance and residual safety aspects of BIOTRONIK products which are used in the context of CSP based on long-term data from an unselected, real-life clinical set-up.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Guideline indication for pacemaker or cardiac resynchronization therapy with or without defibrillation function (CRT-P/-D)

Patient is intended for a de novo implantation and LBBAP therapy with an investigational generator and an investigational lead OR has just been implanted with an investigational generator and an investigational lead positioned permanently deep within the intraventricular septum and has not yet been discharged from the hospital OR transitions from the BIO|MASTER.CSP study

Ability to understand the nature of the study

Ability and willingness to perform all follow-up visits

Disqualifiers

Planned dation from intended use

Planned for cardiac surgical procedures, heart transplantation or interventional measures other than the study procedure within one year after enrollment

Life-expectancy less than 12 months

Pregnant or breast feeding

Trial population

The patient population consists exclusively of patients with an indication for pacemaker or cardiac resynchronization therapy according to the current clinical practice.

Trial design

Design model

Other

Time perspective

Prospective

Treatments tested in this trial

  • Implantation of the Solia CSP S pacing lead for LBBAP

    Device

    Observation of clinical routine care for patients implanted with BIOTRONIK devices used for conduction system pacing (CSP)

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

SADE-d free rate related to any investigatonal device

Rate of serious adverse device effects possible, probable or causal related to any investigational device.

Time frame
throughout study duration, average of 4 years; annual evaluations
2

Rate of successful acute implantation in LBBAP using investigational devices in LBBAP

All implantations, in which the investigator decides to leave the Solia CSP S pacing lead permanently deep within the intraventricular septum are counted as acute success.

Time frame
Day 1
3

Capture type at implantation

The investigator confirms the type of pacing capture for any implantation in which the pacing lead is permanently positioned deep within the interventricular septum. Success rates for LBBAP and CSP are determined based on ECG parameters.

Time frame
Day 1
4

Long-term maintenance of LBBAP

The investigator is asked to assess the effectiveness of LBBAP during follow-up based on the interpretation of a 12-lead ECG recording.

Time frame
throughout study duration, average of 4 years; annual evaluations

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.