Carotid Ultrasound for Post-Spinal Anesthesia Hypotension in Elderly Hip Surgery

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age65+
SponsorTanta University

About this trial

This study aims to evaluate the predictability of preoperative carotid artery-corrected flow time (CFTc) for hypotension after spinal anesthesia in patients undergoing geriatric hip replacement surgery.

Primary outcomes:

• The predictive performance of preoperative CFTc for post-spinal hypotension .

Secondary outcomes:

* Cut-off value, sensitivity, specificity, positive predictive value and negative predictive value of CFTc in prediction of hypotension. * Cut-off value, sensitivity, specificity, positive predictive value and negative predictive value of IVC collapsibility. * Cut-off value, sensitivity, specificity, positive predictive value and negative predictive value of echocardiography (ECHO) (LVOT-VTI). * Comparison of predictive accuracy of CFTc, IVC, and ECHO for post-spinal hypotension. * Monitoring of systolic blood pressure (SBP), mean arterial pressure (MAP), and heart rate (HR) (first 10 min every 2 minutes, then at 15 min and at 20 min).

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients aged 65 years or older

Both sexes

Scheduled for elective hip replacement surgery under spinal anesthesia

American Society of Anesthesiologists (ASA) physical status classification I, II, or III

Disqualifiers

Patient refusal to participate

Severe carotid artery stenosis (> 50%)

Cardiac arrhythmias

Severe valvular heart disease

Trial population

Geriatric patients aged 65 years and older of either sex scheduled for elective hip replacement surgery under spinal anesthesia at the Anesthesia Department of Tanta University Hospital.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Ultrasound

    Device

    Preoperative point-of-care ultrasonography is performed using a diagnostic ultrasound system (SONY, General Electric (GE) Medical Systems) to evaluate baseline intravascular volume and hemodynamic status before spinal anesthesia. A high-frequency linear ultrasound probe is positioned over the common carotid artery proximal to its bifurcation to record pulsed-wave Doppler waveforms, measuring flow time from systolic upstroke to the dicrotic notch and calculating the corrected carotid flow time (CFTc) using Wodey's formula across three averaged cycles. The ultrasound device is additionally used with a 2-4 megahertz (MHz) transducer to measure the inferior vena cava collapsibility index (IVCCI) via subcostal M-mode imaging during an inspiratory sniff, as well as the left ventricular outflow tract velocity time integral (LVOT-VTI) via apical five-chamber echocardiography, to determine their accuracy in predicting post-spinal anesthesia hypotension.

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Predictive Performance of Preoperative Corrected Carotid Flow Time (CFTc) for Post-Spinal Hypotension

Carotid flow time is measured preoperatively via pulsed-wave Doppler ultrasound of the common carotid artery. A high-frequency linear ultrasound probe is positioned over the common carotid artery proximal to its bifurcation. The flow time is measured from the systolic upstroke to the dicrotic notch and is then corrected for heart rate using Wodey's formula across three averaged cycles.

Time frame
Preoperative (Baseline, before spinal anesthesia).

Secondary outcomes

1

Optimal Cut-Off Value of Corrected Carotid Flow Time (CFTc)

Evaluation of the diagnostic performance of preoperative CFTc to predict post-spinal anesthesia hypotension. CFTc is measured preoperatively via pulsed-wave Doppler ultrasound of the common carotid artery and corrected using Wodey's formula. Hypotension is defined as a reduction in systolic blood pressure (SBP) greater than 20% from baseline or a mean arterial pressure (MAP) \< 65 mmHg.

Time frame
Within the first 20 minutes following spinal anesthesia.
2

Optimal Cut-Off Value of Inferior Vena Cava Collapsibility Index (IVCCI)

Evaluation of the diagnostic performance of preoperative IVCCI to predict post-spinal anesthesia hypotension. IVCCI is assessed preoperatively using subcostal M-mode ultrasonography during an inspiratory sniff.

Time frame
Within the first 20 minutes following spinal anesthesia.
3

Optimal Cut-Off Value of Left Ventricular Outflow Tract Velocity Time Integral (LVOT-VTI)

Evaluation of the diagnostic performance of preoperative LVOT-VTI to predict post-spinal anesthesia hypotension. LVOT-VTI is measured preoperatively via apical five-chamber echocardiography.

Time frame
Within the first 20 minutes following spinal anesthesia.
4

Comparison of Area Under the Curve (AUC) for CFTc, IVCCI, and LVOT-VTI

The predictive accuracy of CFTc, IVCCI, and LVOT-VTI for post-spinal hypotension will be compared using Receiver Operating Characteristic (ROC) curve analysis to contrast their respective Areas Under the Curve (AUC).

Time frame
Within the first 20 minutes following spinal anesthesia.