1. Research background: Digital workflows integrating precise modeling, virtual design and computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication have substantially improved restoration fit and clinical efficiency. Nevertheless, contemporary digital workflows still present limitations in occlusal reconstruction. Conventional CAD/CAM relies largely on static occlusal data points, which leads to mismatches between restorations and patients' actual functional mandibular pathways. Accordingly, dynamically guided occlusal reconstruction has become a key objective for enhancing the long-term stability and comfort of implant-supported rehabilitations. Particularly during the definitive restoration phase for edentulous patients, occlusal interactions between the implant superstructure and the opposing dentition exert a major influence on clinical chair time and patient satisfaction. Recently, high-precision digital mandibular motion analysis systems have emerged as effective solutions to address these challenges. Ultrasound-based mandibular tracking systems (e.g., Zebris JMA Optic) enable real-time capture of six-degrees-of-freedom mandibular movement and offer superior patient comfort compared with conventional electronic axiographic systems. Alternative technologies employ facial scanners to track spatial displacements of intraoral fiducial markers in real time. Meanwhile, facial scan data, dental cast scan data and CBCT data are registered and fused based on anterior dental anatomical landmarks, allowing direct visualization and recording of the true kinematic trajectories of the mandible and bilateral condyles on the three-dimensional CBCT model. This approach eliminates the need for a facebow or head-mounted apparatus and may provide improved comfort. The newly launched MetiSmile-MR/e-Motion platform by SHINING 3D acquires mandibular movement trajectories via the aforementioned multimodal data registration and fusion; however, its clinical performance in full-arch implant rehabilitation remains to be further validated. 2. Research objective: This study aimed to evaluate the clinical efficacy of mandibular movement trajectories captured by two different digital technologies for dynamic occlusal design in maxillary full-arch implant rehabilitation. In addition, the potential benefits of these digitally recorded mandibular trajectories for dynamic occlusal design were assessed in terms of functional stability and patient satisfaction in full-arch implant rehabilitation, by examining mandibular pathways after definitive restoration delivery and patients' subjective comfort. Based on the above outcome measures, this study further evaluated whether the SHINING 3D multimodal data registration and fusion workflow could serve as an alternative to the electronic facebow for dynamic occlusal design in full-arch implant rehabilitation. 3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study..Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. For all included patients, at the definitive impression stage, mandibular movement trajectories were captured using two different digital technologies. The trajectory datasets obtained from both digital approaches were imported into Exocad software for the design of definitive restorations. After the definitive restorations were inserted intraorally, panoramic radiographs were taken to confirm complete seating of the restorations. The restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency. Once satisfactory occlusion was achieved, the restorations were rescanned to acquire post-adjustment digital models. A one-month follow-up visit after definitive restoration delivery was arranged to evaluate the stability of mandibular movement trajectories captured by the different digital workflows.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Edentulous patients or patients with end-stage periodontitis aged ≥ 18 years, whose oral conditions are suitable for fixed implant-supported full-arch rehabilitation.

Absence of severe systemic diseases, including uncontrolled diabetes mellitus, severe hypertension, cardiac disease, or a history of craniomaxillofacial radiotherapy.

Patients scheduled to receive fixed implant-supported maxillary full-arch rehabilitation, with or without simultaneous mandibular full-arch implant-supported fixed rehabilitation, and to be delivered with an acrylic resin maxillary full-arch provisional restoration within 24 h after surgery.

Patients who are able to understand and actively cooperate with treatment procedures and have provided written informed consent.

Disqualifiers

Patients retaining acrylic resin restorations as definitive restorations.

Patients unable to cooperate with the mandibular motion analysis system for mandibular movement trajectory capture.

Trial design

Design model

Parallel

Treatments tested in this trial

  • the Zebris electronic facebow

    Device

    At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

  • the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow

    Device

    At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow.

Treatment groups

24 Participants
are divided into 2 treatment groups
Group A: Zebris electronic facebow groupSham comparator 1 intervention
Group B: SHINING 3D intraoral scan-facial scan-CBCT fusion multimodal workflow groupExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Occlusal Adjustment Depth and Area

After insertion of the definitive restorations, the restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. A 3D metrological analysis software package (Geomagic Control X 2022) was used for registration and analysis of the digital models obtained before and after occlusal grinding. Occlusal grinding depth (μm) was quantified and reported as the mean absolute error (MAE, representing the mean occlusal grinding depth) and root mean square (RMS) value; occlusal grinding area (mm²) was also calculated.

Time frame
From enrollment

Secondary outcomes

1

Occlusal Adjustment Time

After insertion of the definitive restorations, the restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. Once satisfactory occlusion was achieved, the restorations were rescanned to obtain post-adjustment digital models. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency.

Time frame
From enrollment
2

Stability of mandibular movement trajectories

At the one-month follow-up after definitive restoration delivery, mandibular movement trajectories were remeasured once stable occlusion was confirmed. These measurements were compared with the baseline trajectories recorded during the provisional phase (after stabilization of the provisional restoration and prior to definitive restoration) to evaluate the stability of mandibular trajectories captured by the different digital workflows.

Time frame
From enrollment
3

Patients' subjective comfort

The visual analogue scale (VAS) was used to assess patient comfort during mandibular trajectory acquisition.

Time frame
From enrollment

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Fuming He

Lead sponsor

The Dental Hospital of Zhejiang University School of Medicine

Sponsor institution

This trial is not recruiting at the moment. You can still explore other options: