Clinical trials

4

Search and review clinical trials. Use filters to narrow results by trial status, phase, treatment, biological sex and sponsor.

Condition / disease
Location
Status: Not yet recruiting

Clinical Outcomes of Digitally Recorded Mandibular Trajectories for Dynamic Occlusal Design in Full-Arch Implant Rehabilitation

1. Research background: Digital workflows integrating precise modeling, virtual design and computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication have substantially improved restoration fit and clinical efficiency. Nevertheless, contemporary digital workflows still present limitations in occlusal reconstruction. Conventional CAD/CAM relies largely on static occlusal data points, which leads to mismatches between restorations and patients' actual functional mandibular pathways. Accordingly, dynamically guided occlusal reconstruction has become a key objective for enhancing the long-term stability and comfort of implant-supported rehabilitations. Particularly during the definitive restoration phase for edentulous patients, occlusal interactions between the implant superstructure and the opposing dentition exert a major influence on clinical chair time and patient satisfaction. Recently, high-precision digital mandibular motion analysis systems have emerged as effective solutions to address these challenges. Ultrasound-based mandibular tracking systems (e.g., Zebris JMA Optic) enable real-time capture of six-degrees-of-freedom mandibular movement and offer superior patient comfort compared with conventional electronic axiographic systems. Alternative technologies employ facial scanners to track spatial displacements of intraoral fiducial markers in real time. Meanwhile, facial scan data, dental cast scan data and CBCT data are registered and fused based on anterior dental anatomical landmarks, allowing direct visualization and recording of the true kinematic trajectories of the mandible and bilateral condyles on the three-dimensional CBCT model. This approach eliminates the need for a facebow or head-mounted apparatus and may provide improved comfort. The newly launched MetiSmile-MR/e-Motion platform by SHINING 3D acquires mandibular movement trajectories via the aforementioned multimodal data registration and fusion; however, its clinical performance in full-arch implant rehabilitation remains to be further validated. 2. Research objective: This study aimed to evaluate the clinical efficacy of mandibular movement trajectories captured by two different digital technologies for dynamic occlusal design in maxillary full-arch implant rehabilitation. In addition, the potential benefits of these digitally recorded mandibular trajectories for dynamic occlusal design were assessed in terms of functional stability and patient satisfaction in full-arch implant rehabilitation, by examining mandibular pathways after definitive restoration delivery and patients' subjective comfort. Based on the above outcome measures, this study further evaluated whether the SHINING 3D multimodal data registration and fusion workflow could serve as an alternative to the electronic facebow for dynamic occlusal design in full-arch implant rehabilitation. 3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study..Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. For all included patients, at the definitive impression stage, mandibular movement trajectories were captured using two different digital technologies. The trajectory datasets obtained from both digital approaches were imported into Exocad software for the design of definitive restorations. After the definitive restorations were inserted intraorally, panoramic radiographs were taken to confirm complete seating of the restorations. The restorations were three-dimensionally scanned with an intraoral scanner to generate pre-adjustment digital models. The total duration of occlusal adjustment was recorded as an indicator of clinical efficiency. Once satisfactory occlusion was achieved, the restorations were rescanned to acquire post-adjustment digital models. A one-month follow-up visit after definitive restoration delivery was arranged to evaluate the stability of mandibular movement trajectories captured by the different digital workflows.

Participants needed: 24
Trial details
Age: 18+Biological sex: AllType: InterventionalSponsor: Fuming HeUpdated: Nov 20, 2026
Eligibility criteria

Edentulous patients or patients with end-stage periodontitis aged ≥ 18 years, wh... [+3]

Patients retaining acrylic resin restorations as definitive restorations. [+1]

Status: Not yet recruiting

Comparison Evaluation of the Accuracy of Two Digital Technologies of Measuring Sagittal Condylar Inclination in Edentulous Patients

1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology. 2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice. 3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At the time of definitive impression taking, mandibular movement trajectories were captured and left and right sagittal condylar inclination (SCI) values were recorded using the Zebris electronic facebow and the Shining intraoral and facial scanning system, respectively. All measurements were performed by a single experienced operator. Each measurement method was repeated three times per participant, and the average value was calculated for analysis.

Participants needed: 20
Trial details
Age: 18+Biological sex: AllType: ObservationalSponsor: Fuming HeUpdated: Nov 20, 2026Duration: 1 Year
Eligibility criteria

Patients aged 18years or older [+3]

Unable to tolerate transplant surgery (due to systemic diseases such as heart di... [+10]

Status: Not yet recruiting

Clinical Efficacy Assessment of Digitally Fabricated PEEK Barrier Membranes for Guided Bone Regeneration in Severe Bone Defects

1. Research background: Guided bone regeneration (GBR), as a bone augmentation technique, is widely used for the reconstruction of hard-tissue defects in implant dentistry. Terheyden classified bone defects into four types according to the spatial relationship between the defect and the intended implant site. Among these, type 2/4, 3/4, and 4/4 are recommended to be managed with a staged protocol: bone augmentation first, followed by dental implant placement. The selection of barrier membranes for GBR depends on the size of the bone defect, and severe three-dimensional bone deficiencies require additional mechanical support. The digitally fabricated PEEK biological barrier is a product of the world's first digital PEEK bone augmentation system newly developed by Kangtuo Medical Group in 2026. It enables predictable bone gain and contour reconstruction, adapts to irregularly shaped bone defects, and provides complete cell exclusion as well as full soft-tissue isolation without the need for an overlying membrane. The system supports full-workflow planning and clinician-driven design. Being radiolucent, it facilitates sequential observation of bone remodeling, and the device is also easy to retrieve. Nevertheless, its clinical performance following GBR in severe bone defect sites remains to be further evaluated. 2. Research objective: To evaluate the bone stability and soft tissue healing outcomes following guided bone regeneration (GBR) using a digital PEEK biological barrier in sites with severe bone defects. This study aims to provide evidence based references for clinicians when selecting barrier membranes, so as to facilitate optimal clinical decision making for bone augmentation. 3. Study design and methods: Design type: multicentral prospective clinical study. Study duration: 3 years. Start time: From the date of adoption of ethics. End time: 2029. For all included patients, cone beam computed tomography (CBCT) scans and intraoral scans will be performed preoperatively, immediately postoperatively, and at 6-8 months postoperatively.

Participants needed: 26
Trial details
Age: 18-80Biological sex: AllType: InterventionalSponsor: Fuming HeUpdated: Nov 5, 2026
Eligibility criteria

Aged between 18 and 80 years, in good general health or with mild and controllab... [+7]

Pregnancy. [+9]

Status: Not yet recruiting

Impact of Gingival Phenotype on Guided Bone Regeneration in the Maxillary Anterior Region

Research background: Guided bone regeneration (GBR), as a bone augmentation technique, is widely used for reconstructing hard tissue defects in implant placement in the anterior esthetic zone. According to the initial bone defect morphology and soft tissue morphology (e.g., the "gingival biotype") in the maxillary anterior esthetic zone, the clinical outcomes of bone regeneration after implantation can be improved by adjusting the direction of implant placement. Currently, few published studies have investigated the effects of gingival biotype on GBR outcomes; sample sizes and comprehensive analyses are insufficient, and some results are contradictory.2. Research objective: Exploring the influence of gingival biotype on soft and hard tissue dimensional changes following guided bone regeneration in the maxillary anterior region. This study takes gingival biotype as the primary research factor and conducts a prospective cohort comparison between two groups, contrasting the effects of thin versus thick gingival biotypes on soft and hard tissue stability following GBR in the maxillary anterior area. 3. Study design and methods: Design type: prospective clinical study. Study duration: 1 year. Start time: From the date of adoption of ethics. End time: 2027. For all included patients, cone beam computed tomography (CBCT) scans and intraoral scans will be performed preoperatively, immediately postoperatively, and at 3 and 6 months postoperatively.

Participants needed: 30
Trial details
Age: 18-80Biological sex: AllType: ObservationalSponsor: Fuming HeUpdated: Nov 5, 2026Duration: 6 Months
Eligibility criteria

Aged 18 years or older [+6]

Patients who cannot tolerate implant surgery (due to systemic diseases such as h... [+11]