About this trial
The purpose of this randomized clinical trial is to compare the clinical performance and survival of two restorative systems in permanent first molars affected by molar-incisor hypomineralization (MIH) in children aged 8 to 14 years.
MIH is a developmental condition that affects the enamel of permanent first molars and may also affect permanent incisors. Affected molars may develop enamel breakdown, sensitivity, and dental caries and may require restorative treatment.
Children included in the study will have at least two MIH-affected permanent first molars that require direct restorative treatment. In each child, one eligible tooth will be restored with the glass hybrid restorative system EQUIA Forte HT, and the other eligible tooth will be restored with the alkasite restorative system Cention Forte. The restorative system assigned to each tooth will be determined at random.
Restorative treatment will be performed after selective caries removal and under rubber dam isolation. Researchers will compare the two restorations within the same child over time.
The restorations will be evaluated for clinical performance and restoration survival. Follow-up assessments will be performed at 1, 3, 6, 12, 18, 24, and 36 months after treatment.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
None
Disqualifiers
None
Trial design
Parallel
Treatments tested in this trial
Alkasite Restorative System
DeviceCention Forte will be used with Cention Primer for direct restoration of the assigned MIH-affected permanent first molar following selective caries removal under rubber dam isolation. Primer application, material preparation and placement, polymerization/setting, finishing, and polishing will be performed according to the manufacturer's instructions. The restoration will be completed in a single treatment session.
Glass Hybrid Restorative System
DeviceEQUIA Forte HT will be used with EQUIA Forte Coat for direct restoration of the assigned MIH-affected permanent first molar following selective caries removal under rubber dam isolation. Material preparation and placement, setting, finishing, and application of the surface coating will be performed according to the manufacturer's instructions. The restoration will be completed in a single treatment session.
Treatment groups
Trial outcomes
Primary outcomes
Material Fracture and Retention According to Revised FDI Criteria
Material fracture and retention of Cention Forte and EQUIA Forte HT restorations will be evaluated according to the revised Fédération Dentaire Internationale (FDI) criteria. This criterion will be scored from 1 to 5: 1 = clinically excellent/very good, 2 = clinically good, 3 = clinically satisfactory, 4 = clinically unsatisfactory, and 5 = clinically poor. Scores 1-3 are considered clinically acceptable and scores 4-5 clinically unacceptable. Higher scores indicate a less favorable clinical outcome. NA will be recorded when the criterion is not applicable or cannot be evaluated.
Marginal Adaptation According to Revised FDI Criteria
Marginal adaptation of Cention Forte and EQUIA Forte HT restorations will be evaluated according to the revised Fédération Dentaire Internationale (FDI) criteria. This criterion will be scored from 1 to 5: 1 = clinically excellent/very good, 2 = clinically good, 3 = clinically satisfactory, 4 = clinically unsatisfactory, and 5 = clinically poor. Scores 1-3 are considered clinically acceptable and scores 4-5 clinically unacceptable. Higher scores indicate a less favorable clinical outcome. NA will be recorded when the criterion is not applicable or cannot be evaluated.
Proximal Contact Point According to Revised FDI Criteria
Proximal contact point, when applicable, will be evaluated for Cention Forte and EQUIA Forte HT restorations according to the revised Fédération Dentaire Internationale (FDI) criteria. This criterion will be scored from 1 to 5: 1 = clinically excellent/very good, 2 = clinically good, 3 = clinically satisfactory, 4 = clinically unsatisfactory, and 5 = clinically poor. Scores 1-3 are considered clinically acceptable and scores 4-5 clinically unacceptable. Higher scores indicate a less favorable clinical outcome. NA will be recorded when the criterion is not applicable or cannot be evaluated.
Form and Contour According to Revised FDI Criteria
Form and contour of Cention Forte and EQUIA Forte HT restorations will be evaluated according to the revised Fédération Dentaire Internationale (FDI) criteria. This criterion will be scored from 1 to 5: 1 = clinically excellent/very good, 2 = clinically good, 3 = clinically satisfactory, 4 = clinically unsatisfactory, and 5 = clinically poor. Scores 1-3 are considered clinically acceptable and scores 4-5 clinically unacceptable. Higher scores indicate a less favorable clinical outcome. NA will be recorded when the criterion is not applicable or cannot be evaluated.
Secondary outcomes
MIH-Related Hypersensitivity Assessed With the Schiff Cold Air Sensitivity Scale
MIH-related hypersensitivity of the study teeth will be evaluated using the Schiff Cold Air Sensitivity Scale (SCASS). The scale ranges from 0 to 3. A score of 0 indicates absence of hypersensitivity, whereas scores 1-3 indicate the presence of hypersensitivity. Higher scores indicate greater hypersensitivity. SCASS scores will be recorded separately for the paired study teeth at baseline and during follow-up.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: