About this trial
Pulmonary vein isolation is the main treatment of paroxysmal and persistent atrial fibrillation.
The aim of our study is to prospectively compare the efficacy and safety of the 3 options of radiofrequency delivery with QDOT Micro™, with systematic use of catheter stabilization tools and tighter lesions
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patient aged 18 or over
First atrial fibrillation ablation
Paroxysmal atrial fibillation defined as atrial fibrillation lasting less than 48 hours
Early atrial fibrillation defined as atrial fibrillation lastiing between 7 days and 3 months
Disqualifiers
History of atrial fibrillation ablation (surgery or catheter)
Documented left atrial thrombus
Left atrial (LA) diameter > 60mm / LA area > 35cm2 / Left atrial volulme index (LAVI) > 45ml/m2
N/STEMI replacement or angioplasty or valve within 3 months prior to registration
Trial design
Parallel
Treatments tested in this trial
Q-MODE : radiofrequency ablation up to 50W
Procedure/SurgeryThe same device (QDOT Micro™) is used in all 3 arms of this trial. The 3 strategies of radiofrequency delivery within the 3 arms are already used in the standard of care. For patient randomized in this arm, the device is set to Q-MODE option: the intensity of radiofrequency to isolate the pulmonary vein is limited to 50W.
Q-MODE+ : radiofrequency up to 90W
Procedure/SurgeryThe same device (QDOT Micro™) is used in all 3 arms of this trial. The 3 strategies of radiofrequency delivery within the 3 arms are already used in the standard of care. For patient randomized in this arm, the device is set to Q-MODE+ option: the intensity of radiofrequency to isolate the pulmonary vein is limited to 90W.
Hybride Q-MODE/Q-MODE+: radiofrequency ablation up to 50W in the anterior part, and 90W in the posterior part
Procedure/SurgeryThe same device (QDOT Micro™) is used in all 3 arms of this trial. The 3 strategies of radiofrequency delivery within the 3 arms are already used in the standard of care. For patient randomized in this arm, the device is set to "Q-MODE/Q-MODE+" option: the intensity of radiofrequency delivered to isolate the pulmonary vein is limited to 50W in the anterior part and to 90W in the posterior part.
Treatment groups
Trial outcomes
Primary outcomes
Incidence of primary adverse events related to the ablation procedure
Incidence of primary adverse events within 7 days after ablation in the 3 arms
Acute procedural success
Acute procedural success is defined as electrical isolation of all pulmonary veins
Secondary outcomes
Incidence of serious adverse event
Incidence of serious adverse events
Rate of additional lesions
Rate of additional lesions between all targeted veins and per subject
Location of additional lesions
Anatomical location of additional lesions
Use of another catheter
Use of another catheter than QDOT in all targeted veins