About this trial
This randomized controlled trial aims to compare postoperative pain after root canal treatment using two different types of ProTaper file systems: manual (hand-held) and rotary (engine-driven). A total of 186 participants aged 18-60 years with symptomatic irreversible pulpitis (with or without symptomatic apical periodontitis) requiring primary root canal treatment on a single tooth will be enrolled. Participants will be randomly assigned to one of two groups: Group A will receive root canal instrumentation using ProTaper Manual files, and Group B will receive instrumentation using ProTaper Rotary files. Both groups will undergo a standardized single-visit root canal treatment protocol. Postoperative pain will be assessed using a Visual Analogue Scale (VAS) at 6 hours, 12 hours, 24 hours, 48 hours, and 72 hours, and 7 days after treatment. The study hypothesis is that there is no statistically significant difference in postoperative pain between the two instrumentation techniques. The findings will help clinicians choose the most appropriate instrumentation technique to minimize patient discomfort and improve treatment satisfaction
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients aged 18-60 years requiring primary root canal treatment
Disqualifiers
Patients with significant systemic or medical conditions that may affect pain perception, inflammatory response, or endodontic treatment
Trial design
Parallel
Treatments tested in this trial
ProTaper Manual Root Canal Instrumentation
Procedure/SurgeryMechanical preparation of the root canal using ProTaper Manual nickel-titanium hand files (SX, S1, S2, F1, F2, F3) with a progressively tapered convex triangular cross-section. The instrumentation will be performed using a defined crown-down technique according to the manufacturer's recommended sequence. The ProTaper Manual system is a hand-operated nickel-titanium instrumentation system used to mechanically prepare the root canal by manual instrumentation.
ProTaper Rotary Root Canal Instrumentation
Procedure/SurgeryMechanical preparation of the root canal using ProTaper Rotary nickel-titanium files (SX, S1, S2, F1, F2, F3) with a progressively tapered convex triangular cross-section. The instrumentation will be performed using an endodontic motor at manufacturer-recommended speed and torque settings. The ProTaper Rotary system is an engine-driven nickel-titanium instrumentation system used to mechanically prepare the root canal using a progressive rotary motion.
Treatment groups
Trial outcomes
Primary outcomes
Postoperative Pain Intensity (Visual Analogue Scale)
Postoperative pain intensity measured using a 10 cm Visual Analogue Scale (VAS) where 0 = no pain and 10 = worst possible pain. Patients will record pain scores in a diary at 6, 12, 24, 48, and 72 hours, and 7 days after root canal instrumentation. The primary outcome is the comparison of postoperative pain scores between the ProTaper Manual and ProTaper Rotary groups at each assessment interval.
Incidence of Postoperative Pain
Proportion of patients reporting any postoperative pain (VAS \> 0) at each assessment interval. This will be expressed as a percentage and compared between the ProTaper Manual and ProTaper Rotary groups.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: