Comparison of the Effect of Lung-protective Ventilation on Optic Nerve Sheath Diameter in Obese and Non-obese Patients

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age25+
SponsorEskisehir Osmangazi University

About this trial

The gol of this prospective observational study is to evaluate the effect of recruitment maneuvers-employed as part of an intraoperative lung-protective ventilation strategy-and individualized positive end-expiratory pressure (PEEP) on intracranial pressure, as assessed by measuring the optic nerve sheath diameter, in both obese and non-obese patients undergoing laparoscopic surgery.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients over 25 years of age

American Soc,ety of Anesthesiology (ASA) status I-III

Scheduled to undergo laparoscopic abdominal surgery

With an expected pneumoperitoneum duration of ≥1 hour

Disqualifiers

Patients with ocular disease

Patients who have undergone cranial or ocular surgery

Patients with a history of laparotomy

Individuals with bullous lung disease

Trial design

Design model

Parallel

Treatments tested in this trial

  • Alveolar recruitment maneuver and individualized PEEP

    Other intervention

    Following intubation and desufflation, an incremental alveolar recruitment maneuver (ARM) will be performed, in which the driving pressure is kept constant while the PEEP value is increased in a stepwise manner. The ARM will be performed in pressure control mode, maintaining pressure at a steady driving pressure with increments in PEEP until a peak pressure is achieved (35-40 cmH2) with a preestablished maximum PEEP. This will be maintained long enough to reopen the alveoli (5---10 breaths), and then pressure is reduced in a stepwise manner until the ideal PEEP is achieved (this being the PEEP level that produces the best Cdyn at the lowest driving pressure for a particular tidal volume setting)

  • Optic nerve sheath diameter (ONSD)

    Procedure/Surgery

    ONSD will be measured at a standard level of 3 mm behind using a lineer ultrasound transducer. The measurements will be performed by an anesthesiologist experienced in ONSD measurement. The eyes will be covered with drapes; subsequently, using an ultrasound-compatible gel, measurements of both of the patient's eyes will be taken in a transverse and a sagittal plane. The mean of these measurements will then be calculated to determine the ONSD value.

Treatment groups

70 Participants
are divided into 2 treatment groups
Group A: Group OOther 2 interventions
Group B: Group NOther 2 interventions

Trial outcomes

Primary outcomes

1

Optic nerve sheath diameter (ONSD)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Time frame
Perioperative/Periprocedural (t0-after anesthesia induction and entubation)
2

Optic nerve sheath diameter (ONSD)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Time frame
Perioperative/Periprocedural (t1- following the recruitment maneuver and the adjustment of the individualized PEEP value)
3

Optic nerve sheath diameter (ONSD)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Time frame
Perioperative/Periprocedural (t2- at the 30th minute of pneumoperitoneum)
4

Optic nerve sheath diameter (ONSD)

Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound

Time frame
Perioperative/Periprocedural (t3 - after desufflation)

Secondary outcomes

1

MAP

Noninvasive mean arterial pressure (mmHg)

Time frame
Perioperative (Noninvasive mean arterial pressure will be recorded at the times when ONSD measurement is performed)
2

HR

Heart rate (beat/min)

Time frame
Perioperative (Heart rate will be recorded at the times when ONSD measurement is performed)
3

etCO2

End-tidal carbon dioxide levels (mmHg)

Time frame
Perioperative (End-tidal carbon dioxide levels will be recorded at the times when ONSD measurement is performed)

Other outcomes

1

Airway pressures during mechanical ventilation

Ppeak, Pplato, Driving pressure (∆P), PEEP levels (cmH20) will be recorded from the sama ventilation monitor screen

Time frame
Perioperative (Ppeak, Pplato, Driving pressure (∆P), PEEP levels will be recorded at the times when ONSD measurement is performed)
2

Postoperative complications

Postoperative nause and vomiting (PONV)

Time frame
PONV will be questioned at the 24th hours
3

Postoperative complications

Headache

Time frame
Headache will be questioned at the 24th hours
4

Postoperative complications

Visual disturbance

Time frame
Visual disturbance will be questioned at the 24th hours

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: