About this trial
The goal of this observational study is to learn more about how doctors can create a complete electrical block in the heart during catheter ablation procedures used to treat certain abnormal heart rhythms. The main questions it aims to answer are:
* How often do electrical signals continue to travel through a blood vessel around the heart after ablation? * Which ablation applications are most important for achieving a successful electrical block? * How do different procedural factors affect the success of the treatment?
Participants who undergo a catheter ablation procedure as part of their normal medical care may take part in this study. No additional tests, visits, or procedures will be required. Researchers will collect information that is routinely recorded during the procedure to better understand how electrical signals travel in the heart and how ablation procedures can be improved.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥18 years at the time of the ablation procedure.
Diagnosis of paroxysmal AF, persistent AF, or perimitral atrial tachycardia.
Catheter ablation with a planned and performed first-time MI line (lateral mitral annulus to left inferior pulmonary vein) during the index procedure.
Procedure performed at AZ Sint-Jan Brugge AV.
Disqualifiers
Age <18 years.
No attempted MI line during the index procedure.
Prior MI line ablation (redo MI line procedures).
Incomplete or non-interpretable procedural documentation precluding lesion-level analysis.
Trial population
The study population comprises adult patients (≥18 years) with symptomatic AF (paroxysmal, persistent) or perimitral atrial tachycardia (PMAT) undergoing left atrial catheter ablation with a planned first-time mitral isthmus line. Both sexes are eligible without restriction on body weight, BMI, or ethnicity. Patients must have sufficient procedural documentation to allow complete lesion-level data extraction.
Trial design
Cohort
Prospective
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Anatomical Zone of the Effective Coronary Sinus RF Application
Anatomical location of the first epicardial radiofrequency (RF) application within the coronary sinus that is temporally associated with achievement of bidirectional mitral isthmus conduction block. Unit: categorical variable (Superior, Anterior, Inferior, or Posterior zone).
RF Power of the Effective Coronary Sinus RF Application
RF power delivered during the first epicardial coronary sinus RF application that is temporally associated with achievement of bidirectional mitral isthmus conduction block. Unit: Watts (W).
Duration of the Effective Coronary Sinus RF Application
Duration of the first epicardial coronary sinus RF application that is temporally associated with achievement of bidirectional mitral isthmus conduction block. Unit: seconds (s).
Contact Force of the Effective Coronary Sinus RF Application
Mean contact force recorded during the first epicardial coronary sinus RF application that is temporally associated with achievement of bidirectional mitral isthmus conduction block. Unit: grams (g).
Secondary outcomes
Number of Epicardial Coronary Sinus RF Applications
Total number of epicardial radiofrequency (RF) applications delivered within the coronary sinus during the ablation procedure. Unit: number of RF applications (n).
Distribution of Epicardial Coronary Sinus RF Applications
Number of epicardial RF applications delivered within each of the 8 predefined anatomical coronary sinus zones. Unit: number of RF applications per anatomical zone (n).
Cumulative Epicardial Coronary Sinus RF Time
Total cumulative duration of all epicardial RF applications delivered within the coronary sinus. Unit: seconds (s).
Total Procedure RF Time
Total duration of radiofrequency energy delivery during the entire ablation procedure. Unit: seconds (s).
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Sebastien Knecht
Lead sponsor
AZ Sint-Jan AV
Sponsor institution