Continuous Glucose Monitoring Parameter and Oral Glucose Tolerance Testing (OGTT) Parameters in Children and Young Adults With Cystic Fibrosis (CF)

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age10-25
SponsorNorthwell Health

About this trial

As modulator therapies extend the lifespan of CF patients, the detection of complications like Cystic Fibrosis Related Diabetes (CFRD) becomes increasingly vital. The current gold standard for CFRD screening, the 2-hour OGTT, is cumbersome and suffers from low compliance. This study proposes that Continuous Glucose Monitoring (CGM) could offer a more comprehensive, easier, and potentially more compliant screening method. The research aims to correlate various CGM parameters (e.g., time in hyperglycemia) with traditional glycemic markers like OGTT glucose levels, GMI, average glucose, variability, and HbA1c. Additionally, the research seeks to understand patient and parent/guardian preferences for CFRD screening modalities. This prospective observational study will involve CF patients wearing a Dexcom CGM around the time of standard OGTT and HbA1c tests, followed by surveys, with the ultimate goal of paving the way for CGM to improve early detection and management of dysglycemia in CF children.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients with Cystic Fibrosis

10-25 years of age who have obtained or will obtain a OGTT within 3 months of recruitment and CGM placement.

Disqualifiers

Diagnosis of diabetes mellitus type 1 or type 2

Use of the following medication: steroid course, Metformin therapy,

Concurrent CV disease or malignancy, kidney failure, lung transplant.

Does not have access to personal Bluetooth device compatible with Dexcom G7 application.

Trial design

Design model

Single group

Treatments tested in this trial

  • Continuous Glucose Monitor

    Device

    Continuous glucose monitors, such as Dexcom, have been established as a standard component of clinical care for continuous blood glucose monitoring. These devices are widely utilized in diabetes management clinics and demonstrate a robust safety and efficacy profile. The intervention also includes administration of a patient preference survey as outlined in the study protocol.

Treatment groups

30 Participants
are divided into 1 treatment group
Group A: Pediatric Cystic Fibrosis Patients Undergoing Concurrent CGM Monitoring and OGTT TestingExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Average Blood Glucose Level from Continuous Glucose Monitoring

Mean glucose level recorded over the continuous glucose monitoring (CGM) wear period (mg/dL)

Time frame
Up to 10 days of CGM wear (within 3 months of the Oral Glucose Tolerance Test).

Secondary outcomes

1

Percentage of Time Glucose Exceeds 150 mg/dL from Continuous Glucose Monitoring

The proportion of time during the CGM wear period that glucose levels were above 150 mg/dL (%)

Time frame
Up to 10 days of CGM wear (within 3 months of the Oral Glucose Tolerance Test).
2

Percentage of Time Glucose Exceeds 180 mg/dL from Continuous Glucose Monitoring

The proportion of time during the CGM wear period that glucose levels were above 180 mg/dL (%)

Time frame
Up to 10 days of CGM wear (within 3 months of the Oral Glucose Tolerance Test).
3

Fasting Plasma Glucose Level from Oral Glucose Tolerance Test

Plasma glucose level measured after an overnight fast, as part of the Oral Glucose Tolerance Test (OGTT) (mg/dL)

Time frame
Single measurement at the start of the OGTT (within 3 months of CGM wear).
4

1 hour Plasma Glucose Level from Oral Glucose Tolerance Test

Plasma glucose level measured 1 hour after glucose administration as part of the Oral Glucose Tolerance Test (OGTT) (mg/dL)

Time frame
Single measurement 1 hour after glucose load (within 3 months of CGM wear).

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.