Diagnostic Accuracy of Combined Perfusion Index, Internal Jugular Vein Collapsibility Index and Cardiac Index in Predicting Post-Spinal Hypotension During Elective Cesarean Section

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexFemale
Age18-40
SponsorMenoufia University

About this trial

compare Perfusion Index with Internal Jugular Vein Collapsibility Index (IJVCI) as a predictor for post-spinal hypotension in parturient undergoing elective caesarean section.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Full-term pregnant women undergoing elective cesarean section under spinal anesthesia (gestational age >= 37 weeks), singleton pregnancy.

Age: 18-40 years.

ASA I, II.

BMI: 18.5-35 kg/m2.

Disqualifiers

• Patient refusal or inability to provide informed consent.

Emergency cesarean section.

Known contraindications to spinal anesthesia (coagulopathy, local infection, elevated ICP).

Baseline hypotension (SBP < 100 mmHg) prior to spinal anesthesia.

Trial population

Adults undergoing Elective Cesarean Section at Menoufia University Hospitals

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • pulse oximeter to measure Perfusion Index (PI)

    Device

    is measured using a validated multi-parameter monitor with a pulse oximetry module (Mindray uMEC 12 or equivalent). * The probe is placed on the right index finger in the supine position before induction of spinal anesthesia block. * Three consecutive readings are recorded at 1-minute intervals. * These steps will be repeated with another reading after delivery of baby. * Then the mean value is used as the baseline PI. * The cut-off applied is: - * 3.5 or less (low risk for hypotension) * Greater than 3.5 (high risk for hypotension)

Treatment groups

50 Participants
are divided into 2 treatment groups
Group A: Perfusion Index (PI) group measured by pulse oximeter1 intervention
Group B: Internal Jugular Vein Collapsibility Index group will be measured by ultrasonography0 interventions

Trial outcomes

Primary outcomes

1

compare the diagnostic accuracy assessed by ROC curve analysis between Perfusion Index (PI) & Internal Jugular Vein Collapsibility Index (IJVCI) combined with Cardiac Index (CI) in predicting post-spinal hypotension in elective CS patients.

Time frame
• Three consecutive readings are recorded at 1-minute intervals. • These steps will be repeated with another reading after delivery of baby.

Secondary outcomes

1

measure systolic arterial blood pressure changes after spinal anesthesia.

Time frame
immediately after spinal anesthesia
2

Total ephedrine dose or phenylephrine dose /milligram.

Time frame
throughout the operation

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.