Dilation Optimisation for Uniform Bioprosthetic Leaflet Expansion

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorThe Alfred

About this trial

The goal of this clinical trial is to discover if routine 'double tap' balloon post-dilation improves valve expansion and clinical outcomes in adults undergoing Transcatheter Aortic Valve Implantation (TAVI) with the SAPIEN balloon-expandable TAVI prosthesis.

The primary hypothesis is that routine 'double tap' balloon post-dilation improves TAVI valve expansion. The secondary hypothesis is that routine 'double tap' balloon post-dilation improves TAVI valve haemodynamic performance.

Participants will be randomised to balloon-expandable TAVI either with or without routine 'double tap' balloon post-dilation.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Severe aortic stenosis undergoing trans-femoral TAVI using the SAPIEN 3 Ultra/RESILIA balloon-expandable transcatheter heart valve.

Tricuspid or bicuspid aortic valve stenosis

Disqualifiers

Valve-in-valve TAVI for failure of an existing prosthetic surgical or transcatheter valve failure

TAVI performed for native valve aortic regurgitation

High risk 'hostile' annular anatomy as adjudicated by multidisciplinary Heart Team based on pre-procedure CT anatomy.

Trial design

Design model

Parallel

Treatments tested in this trial

  • 'Double tap' balloon post-dilation

    Other intervention

    Routine second inflation of the valve delivery balloon ('double-tap') BPD following balloon-expandable valve TAVI

Treatment groups

250 Participants
are divided into 2 treatment groups
Group A: Routine deploymentNo intervention 0 interventions
Group B: Routine double tapExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Fluoroscopic valve expansion

Percentage (%) final valve expansion measured by fluoroscopy

Time frame
Day 1 post-procedure

Secondary outcomes

1

Haemodynamic performance

Echocardiographic transvalvular mean pressure gradient (mmHg)

Time frame
Day 1-3 post-procedure
2

Haemodynamic performance

Echocardiographic aortic valve area (cmsq)

Time frame
Day 1-3 post-procedure
3

Freedom from cardiovascular death or valve reintervention

Freedom from occurrence of composite of cardiovascular death or valve reintervention

Time frame
1 year and 3 years post-procedure

Other outcomes

1

CT sub-study: final valve expansion measured by non-contrast computed tomography

CT sub-study: final valve expansion (%) measured by non-contrast computed tomography

Time frame
30-90 days post-procedure
2

New permanent pacemaker implantation

New permanent pacemaker implantation

Time frame
30 days post-procedure
3

Stroke

Confirmed stroke

Time frame
30 days post-procedure

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

The Alfred

Lead sponsor

Edwards Lifesciences

Collaborator

This trial is not recruiting at the moment. You can still explore other options: