Dynamic SvO2 in Predicting Fluid Responsiveness in Septic Shock

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorMenoufia University

About this trial

This prospective observational diagnostic accuracy study investigates the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock, compared to measurements obtained using echocardiography (VTI) and cardiometry. We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age > 18 years

Disqualifiers

Pregnancy

Significant valvular heart disease.

Atrial fibrillation.

Inadequate echocardiographic window.

Trial population

This single-center, prospective, observational study will be conducted in the Intensive Care Unit (ICU) at Menoufia University Hospitals. Adults spontaneously breathing patients with septic shock who undergo a fluid challenge as a part of their hemodynamic management in the first 24 hours will be eligible for enrollment. Ethical approval will be obtained from the ethics committee at the Menoufia Faculty of Medicine, and the study will follow ethical guidelines and secure approval from the Institutional Review Board (IRB). Written informed consent will be obtained from each participant or their legal surrogate before study inclusion.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Measuring dynamic central venous oxygen saturation (ScvO2) at baseline and after fluid challenge. Measuring Cardiac output by echocardiography or cardiometry at baseline and after fluid challenge.

    Device

    We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Measuring dynamic central venous oxygen saturation (ScvO2) at baseline and after fluid challenge.

Time frame
After 30 mins

Secondary outcomes

1

Measuring Cardiac output by echocardiography or cardiometry at baseline and after fluid challenge.

We will correlate the changes in measuring cardiac output by both echocardiography and cardiometry with the changes in dynamic central venous oxygen saturation both at baseline and after fluid challenge to investigate the efficacy of dynamic central venous oxygen saturation in predicting fluid responsiveness in septic shock.

Time frame
After 30 mins

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.