About this trial
The purpose of this study is to objectively assess the effects of hip bump manipulation (HBM) on a healthy population aged 18-45 years. We hypothesize that the HBM will improve hip internal rotation passive range of motion, improve the strength of the hip external rotators, decrease compensatory motions in hip flexion during active range of motion, and improve bipodal landing mechanics.
Human participants will be analyzed to determine whether the manipulation produces the intended clinical outcomes. While clinicians commonly use this technique, its effectiveness has yet to be substantiated through research. This technique is a high velocity low amplitude thrust to the greater trochanter which theorizes the quick stretch of the external rotator muscles and may improve a malpositioned femoral head within the acetabulum. These improvements may positively affect functional movements such as bipodal landing.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Healthy individuals
Aged 18-45 years old
Disqualifiers
Diagnosed demoroacetabular labral tear
Diagnosed osteoarthritis (OA)
Current or recent (within the past 6 months) low back pain
Hip or pelvic pain
Trial design
Parallel
Treatments tested in this trial
Hip Bump Manipulation
Procedure/SurgeryThis technique is a high velocity low amplitude thrust (HVLAT) directly posterior to the greater trochanter which theorizes the quick stretch of the external rotator muscles and may improve a malpositioned femoral head within the acetabulum.
Sham (No Treatment)
Procedure/SurgeryIliac Crest Sham Manipulation
Treatment groups
Trial outcomes
Primary outcomes
Hip External Rotation Strength
Measured with ActivForce Handheld Dynamometry. 3 trials for an average Mean Voluntary Isometric Contraction
Hip Internal Rotation Range of Motion
Hip Internal rotation measured in a seat position 90/90 position. Measured with IPhone Digital Goniometry. 3 trials with a calculated average
Hip EMG Muscle Activation
Delsys Trigno Wireless System will be used to monitor changes in muscle activation between the Tensor Fascia Latae, Gluteus Medius, and Gluteus Maximus. During seated isometric external rotation contraction and bipodal landing. EMG will be retrieved on the 2nd attempt out of 3 trials.
Bipodal Landing
Kinvent K-Delta Force Plates used to measure changes in bipodal landing mechanics including force distribution, time to stabilization, etc. 3 trials will be conducted to present average values
Secondary outcomes
Hip Deviation with Active Assisted Hip Flexion Range of Motion
Deviation resulting in excessive abduction and external rotation during knee to chest active assisted range of motion. Video recording before and after to observe changes pre and post intervention.
Hip External Rotation Range of Motion
Measured to compare the change in External and Internal Rotation range of motion relationship. Measure with iPhone Digital Goniometry. 3 trials will be conducted to present an average value of ROM
Sponsors and contacts
Click on the lead sponsor to view all of their trials.