Effects of Respiratory Muscle Training on Tongue Muscle Function

ConditionHealthy
Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-65
SponsorUniversité Catholique de Louvain

About this trial

This study aims to investigate the effects of respiratory muscle training on tongue muscle function in healthy subjects. We hypothesize that respiratory muscle training can improve strength and endurance of the tongue muscles.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

None

Disqualifiers

None

Trial design

Design model

Parallel

Treatments tested in this trial

  • IMT

    Device

    Description: A pressure threshold loading device will be used: the POWERbreathe Medic (load range 10-90 cmH2O). Participants will be instructed to exhale passively during normal tidal breathing through the training device (until functional residual capacity) and to perform deep inspirations against the external load. The first week, the resistance will be fixed at 30% of the baseline measured maximal inspiratory pressure (MIP). Participants will be instructed to increase the resistance by 10% of the baseline set resistance each week.

  • EMT

    Device

    A pressure threshold loading device will be used: the POWERbreathe Ex1 EMT Medic (load range 10-90 cmH2O) or POWERbreathe Ex1 EMT MR (load range 35-175 cmH2O) depending on their baseline MEP measurement. Participants will be instructed to inhale quietly during normal tidal breathing through the training device and to perform rapid and deep exhalation against the external load. The first week, the resistance will be fixed at 30% of the baseline measured MEP. Participants will be instructed to increase the resistance by 10% of the baseline set resistance each week.

  • Sham

    Device

    A pressure threshold loading device will be used: the POWERbreathe Ex1 EMT Medic or MR, but with the resistance mechanism inside removed and replaced by a plastic ball. The same instructions will be given as for the EMT group, except that there will be no or minimal resistance (less than 6 cmH2O). There will be no change in resistance over the weeks.

Treatment groups

60 Participants
are divided into 4 treatment groups
Group A: IMTActive comparator 1 intervention
Group B: EMTActive comparator 1 intervention
Group C: ShamSham comparator 1 intervention
Group D: ControlNo intervention 0 interventions

Trial outcomes

Primary outcomes

1

Tongue elevation strength

Tongue elevation strength (peak pressure) will be measured via the Iowa Oral Performance Instrument (IOPI).

Time frame
Measured two times: at baseline and after 8 weeks

Secondary outcomes

1

Tongue protrustion strength

Tongue protrusion strength (peak pressure) will be measured via the Iowa Oral Performance Instrument (IOPI).

Time frame
Measured two times: at baseline and after 8 weeks
2

Tongue elevation endurance

Tongue elevation endurance (50% of peak pressure) will be measured via the Iowa Oral Performance Instrument (IOPI).

Time frame
Measured two times: at baseline and after 8 weeks
3

Tongue protrusion endurance

Tongue protrusion endurance (50% of peak pressure) will be measured via the Iowa Oral Performance Instrument (IOPI).

Time frame
Measured two times: at baseline and after 8 weeks
4

Maximal inspiratory pressure

Maximal inspiratory pressure will be measured at functional residual capacity (FRC)

Time frame
Measured two times: at baseline and after 8 weeks

Other outcomes