About this trial
This study aims to determine the simultaneous effects of transcutaneous auricular vagus nerve stimulation (taVNS) at two frequencies (30 Hz and 100 Hz) compared to sham stimulation on cognitive functions, dual-task performance, and interoceptive accuracy in healthy adults. taVNS non-invasively activates vagal afferent fibers through electrical stimulation of the outer ear (cymba conchae and tragus), which are exclusively innervated by the auricular branch of the vagus nerve. Its proposed mechanism involves activation of the locus coeruleus-norepinephrine system and insular/prefrontal projections, providing a putative neurobiological basis for cognitive modulation. Ninety healthy volunteers (18-45 years) will be randomly assigned to one of three parallel groups: sham taVNS (n=30), active 30 Hz taVNS (n=30), or active 100 Hz taVNS (n=30). Each participant completes two sessions separated by one week: Session 1 (baseline, no stimulation) and Session 2 (experimental, stimulation active). Assessments include dual-task cost (3-Meter Tandem Walk Test with serial subtraction), executive function (Stroop Test), processing speed (Deary-Liewald Reaction Time Task), interoceptive accuracy (Heartbeat Counting Task), and heart rate variability (Polar H10). Sleep quality (PSQI), depression (BDI), physical activity (IPAQ-SF), and fatigue (Chalder Fatigue Scale) are measured at baseline as potential moderators. This is the first double-blind, sham-controlled study to simultaneously evaluate the effects of taVNS on these three constructs within a single experimental design, and the comparative frequency analysis (30 Hz vs 100 Hz) will contribute to parameter optimization for taVNS applications.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
1. Age 18-45 years 2. Mini-Mental State Examination (MMSE) score >24 3. Willing to participate; signed written informed consent 4. No uncorrected vision problems (glasses or contact lenses acceptable) 5. No communication difficulties; native Turkish speaker
Disqualifiers
1. Cardiovascular disease or history (arrhythmia, conduction block, hypertension, cardiac diagnosis) 2. Any implanted electronic device or metal implant in the head/neck (pacemaker, cochlear implant, ventricular shunt, etc.) 3. Neurological disease or history of neurological procedures (epilepsy, stroke, TIA, migraine, brain surgery, progressive neurological disease) 4. Psychiatric diagnosis (schizophrenia, bipolar disorder, major depressive disorder, OCD, etc.) 5. History of vagotomy or prior vagus nerve stimulation 6. Current use of medications affecting the autonomic or central nervous system (beta-blockers, antiarrhythmics, antidepressants, antiepileptics, sedatives, etc.) 7. Systemic disease affecting autonomic function (diabetes, etc.) 8. Local conditions at stimulation site: acute tinnitus, ear or facial pain, ear trauma, skin lesion or infection, anatomical anomaly, or ear piercing at stimulation site 9. Chronic or acute musculoskeletal pain (neck/low back pain, fibromyalgia, joint disease, etc.) 10. Pregnancy or breastfeeding 11. Alcohol or substance use disorder 12. Concurrent enrollment in another interventional study 13. Vigorous physical exercise within 24 hours before assessment 14. Inability to understand or adhere to study protocol
Trial design
Parallel
Treatments tested in this trial
Sham Stimulation
DeviceSham transcutaneous auricular vagus nerve stimulation delivered via Vagustim® non-invasive stimulation device (CE No: 2460; Vagustim Health Technologies Inc., Turkey). Electrode placement is identical to active groups: bilateral cymba conchae and tragus using custom-sized auricular electrodes (small/medium/large). The device is switched on and electrodes are positioned in the same manner, but no electrical current is delivered. Session duration and all procedural steps are identical to active arms to maintain blinding. Participants are not informed of group allocation. The outcome assessor is blinded to group assignment throughout the study.
taVNS 30 Hz
DeviceActive transcutaneous auricular vagus nerve stimulation at 30 Hz delivered via Vagustim® non-invasive stimulation device (CE No: 2460; Vagustim Health Technologies Inc., Turkey). Electrode placement: bilateral cymba conchae and tragus using custom-sized auricular electrodes (small/medium/large). Parameters: frequency 30 Hz, pulse width 250 µs, continuous mode, current intensity individually titrated to a perceptible but sub-pain threshold. Stimulation is applied online (throughout the experimental session) during all outcome assessments. The outcome assessor is blinded to group allocation; stimulation is administered by a separate researcher not involved in assessments.
taVNS 100 Hz
DeviceActive transcutaneous auricular vagus nerve stimulation at 100 Hz delivered via Vagustim® non-invasive stimulation device (CE No: 2460; Vagustim Health Technologies Inc., Turkey). Electrode placement: bilateral cymba conchae and tragus using custom-sized auricular electrodes (small/medium/large). Parameters: frequency 100 Hz, pulse width 250 µs, continuous mode, current intensity individually titrated to a perceptible but sub-pain threshold. Stimulation is applied online (throughout the experimental session) during all outcome assessments. The outcome assessor is blinded to group allocation; stimulation is administered by a separate researcher not involved in assessments.
Treatment groups
Trial outcomes
Primary outcomes
Dual-Task Cost on 3-Meter Tandem Walk Test
Dual-Task Cost (DTC, %) quantifies the decrement in tandem walking performance when simultaneously performing serial subtraction (counting backward by 3s from a 3-digit number). DTC (%) = \[(single-task time - dual-task time) / single-task time\] × 100. Higher DTC indicates greater cognitive-motor interference.
Stroop test
Executive function assessed via Stroop Test (Stroop Anchor Form). The Stroop effect is the difference in response time and accuracy between the color-word incongruent and congruent conditions, reflecting inhibitory control capacity.
Simple and Choice Reaction Time - Deary-Liewald Task
Processing speed assessed using the Deary-Liewald Reaction Time Task administered via psytoolkit.org. Two conditions: Simple Reaction Time (SRT: respond to single stimulus appearing on blue background) and Choice Reaction Time (CRT: respond to one of four stimuli with the corresponding key). Inter-stimulus interval randomized between 1-3 seconds.
Heartbeat Counting Task Score (Interoceptive Accuracy)
Objective interoceptive accuracy assessed using the Schandry (1981) Heartbeat Counting Task. Participants silently count their own heartbeats during 25-, 35-, and 45-second intervals without external cues. Reported counts are compared with actual heart rate recorded via Polar H10 sensor. Accuracy score = 1 - \[Σ(\|reported - actual\| / actual)\] / 3. Scores range 0-1; higher scores indicate greater interoceptive accuracy.
Secondary outcomes
Resting Heart Rate Variability
HRV assessed as an index of autonomic nervous system regulation using Polar H10 heart rate sensor (Polar Electro Oy, Kempele, Finland) synchronized via Bluetooth with the "ECG Analysis for Polar H10" smartphone application. Participants rest in a supported seated position for 1 minute after sensor calibration. Time-domain and frequency-domain HRV indices extracted.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: