Evaluation of Visual Outcomes, Complications, and Neuroadaptation Following Bilateral Implantation of enVista Envy Trifocal Intraocular Lenses

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age50-75
SponsorPomeranian Medical University Szczecin

About this trial

The enVista Envy intraocular lens (IOL) manufactured by Bausch + Lomb is a new multifocal intraocular lens based on diffractive optics. It was registered with the Polish Office for Registration of Medicinal Products, Medical Devices and Biocidal Products in September 2025. The lens also bears the CE mark, indicating that it is approved for marketing and use within the European Union.

Its innovative design is based on a smooth, continuous transition between diffractive rings, allowing patients to achieve excellent visual quality at far, intermediate, and near distances while reducing the incidence and severity of unwanted photic phenomena such as glare and halos. Thanks to this technology, patients may achieve better uncorrected visual acuity, reduced dependence on spectacles, and faster neuroadaptation.

The Second Department of Ophthalmology is the first center in Poland to be offered participation in a clinical study evaluating the safety and effectiveness of the enVista Envy IOL. The planned study will provide the first clinical experience with this lens in Poland and contribute to expanding knowledge regarding modern intraocular lens technologies.

Twenty patients will be selected according to predefined inclusion and exclusion criteria. Preoperative assessment will include a comprehensive ophthalmic examination and IOL power calculation. Cataract surgery will be performed using bimanual MICS (Micro-Incision Cataract Surgery) phacoemulsification. Surgery in the fellow eye will be performed one month after the first procedure.

Before surgery and during follow-up visits at 1, 3, and 6 months postoperatively, the following assessments will be performed: routine ophthalmic examination, intraocular pressure (IOP) measurement, visual evoked potentials (VEP), monocular and binocular uncorrected distance visual acuity (UDVA), distance best-corrected visual acuity (DBCVA) at 4 meters, intermediate visual acuity (66 cm) and near visual acuity (40 cm), both corrected and uncorrected, monocularly and binocularly (logMAR charts), binocular contrast sensitivity testing, and defocus curve assessment.

Intraoperative and postoperative complications, quality of vision (using the standardized Quality of Vision Questionnaire \[QoV\] and the Near Activity Vision Questionnaire \[NAVQ\]), speed of neuroadaptation, spectacle independence, and the occurrence of photic phenomena such as glare and halos will also be analyzed.

Eligibility criteria

Qualifiers

Bilateral cataract or refractive lens exchange candidates.

Presbyopia and/or hyperopia.

Preoperative corneal astigmatism less than 1.00 diopter (D).

Absence of ocular diseases other than cataract.

Disqualifiers

Glaucoma.

Amblyopia.

Macular diseases (including macular degeneration and other macular pathology).

Angle kappa greater than 0.5 mm.

Trial design

Treatments tested in this trial

  • cataract surgery

Treatment groups

20 Participants
are divided into 1 treatment group