Impact of Belt Position on the Results of PEEP Titration by EIT During ARDS

ConditionARDS
Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorCentre Hospitalier Saint Joseph Saint Luc de Lyon

About this trial

ARDS is a frequent reason for hospitalization in intensive care. In order to improve its management, doctors seek to limit the mechanical ventilation-induced injuries (VILI) that can occur. PEEP is a parameter that plays a role in the appearance of VILI, and its adjustment can be optimized by EIT. The EIT is a non-invasive, non-irradiating, real-time monitoring device, today widely used for the optimization of ventilation in patients intubated for ARDS. The positioning of the EIT belt at different chest heights could influence the result of the PEEP titration.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Occurrence of moderate to severe ARDS (PaO2/FiO2 ratio ≤ 200 mmHg) within 72 hours following intubation

Criteria for moderate to severe ARDS for less than 72 hours

Passive ventilation in controlled assisted ventilation (no spontaneous ventilation)

Consent of next of kin

Disqualifiers

Age < 18 years

ECMO

Pneumothorax

Pacemaker or implantable defibrillator

Trial design

Design model

Single group

Treatments tested in this trial

  • EIT

    Device

    Two PEEP titrations monitored by EIT will be performed, each with the electrode belt positioned at a different chest height (2nd intercostal space or 5th intercostal space). The order will be drawn at random.

Treatment groups

20 Participants
are divided into 1 treatment group
Group A: PEEP titrationsOther 1 intervention

Trial outcomes

Primary outcomes

1

Impact of the position of the electrode belt on the results of PEEP titration by EIT.

Optimal PEEP determined by PEEP titration using the crossing point method.

Time frame
Day 0

Secondary outcomes

1

Impact of the existence of intra-tidal recruitment on the discordance between PEPEIT and PEPCRS

Variability of the impedance variation during insufflation of the tidal volume ("tidal impedance variation) during titration measured by the relative interquartile coefficient (Q3-Q1)/median

Time frame
Day 0
2

Factors associated with a discordance between PEPEIT and PEPCRS

Variability of the impedance variation during insufflation of the tidal volume ("tidal impedance variation) during titration measured by the relative interquartile coefficient (Q3-Q1)/median

Time frame
Day 0
3

Discrepancy between compliance measured according to impedance and compliance measured according to exhaled volume

Regional ventilation delay (RVD)

Time frame
Day 0

Other outcomes

Locations

This trial has no locations.