Open Surgical, Modified Seldinger's and US Techniques for Jugular Central Line Insertion in Infants

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age1-18
SponsorTanta University

About this trial

The aim of this study was to compare the three approaches: open technique, modified Seldinger's technique and closed ultrasound-guided Central venous catheterization insertion for central line insertion in infancy as regards safety, success of cannulation, technique time, and preservation of the patency of the internal jugular vein.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

None

Disqualifiers

1- femoral or subclavian Central venous catheterization insertion. 2- patients with thrombosed internal jugular vein . 3- patients with previous Central venous catheterization insertion. 4- those with malignant conditions

Trial design

Design model

Parallel

Treatments tested in this trial

  • Open surgical cut down technique

    Device

    The technique was performed following the descriptions of Farhadi et al. The infant was positioned in 30° (Trendelenburg's position), with a roll under his shoulders for neck extension and rotated to contralateral side of the surgical side to expose the incision site. Incision was done under sedation and pulse oximeter to monitor the oxygen saturation during the technique. Under complete aseptic technique, a small transverse incision 1cm was made on triangle bordered by the clavicle inferiorly and by the sternal and clavicular heads of the sternomastoid muscle medially and laterally. With blunt dissection we separate the two heads of the sternomastoid exposing the internal jugular vein . Then internal jugular vein cut down was performed and catheter inserted through it, all internal jugular vein venotomies were repaired as needed by 6/0 Polypropylene (Prolene®) suture and the wound was closed by absorbable polyglactin (Vicryl) suture

  • Modified Seldinger's technique

    Device

    After proximal and distal control of the vein, a 24-G. cannula was carefully inserted directly to the internal jugular vein . The guidewire was inserted through the cannula, then the cannula was removed. A size 4-5 French short length catheter was passed and brought out through the guidewire, then the guidewire was removed. The wound was closed after the correct catheter position and good haemostasis was obtained; the area was covered with sterile dressing.

  • Closed Ultrasound guided CVC insertion

    Device

    Ultrasound probe was connected to ultrasound unit and focused with ultrasonic gel and wrapped in a sterile plastic sheath. By wrapping the transducer in a sterile sheath, the probe place perpendicular to the long axis of the vessel, standard US two-dimensional (2D) imaging was used to visualize the vein in the short-axis view as a circle. Catheterization was performed under continuous dynamic observation of real-time 2D images. Insertion needle was advanced through the skin under US guidance into the internal jugular vein . A guidewire was then placed through the needle into the vein, and the needle was removed. Then catheter was inserted over the wire into internal jugular vein .

Treatment groups

35 Participants
are divided into 3 treatment groups
Group A: Open surgical technique groupExperimental treatment 1 intervention
Group B: Modified Seldinger's technique groupExperimental treatment 1 intervention
Group C: Ultrasound guided Central venous catheterization insertion groupExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

success of cannulation

Central venous cannulations in pediatric patients using each technique

Time frame
20 minutes

Secondary outcomes

1

Technique time

Time frame
within 30 minutes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: