About this trial
The main purpose of this investigation is to support safety and performance assessment of the investigational device with a focus on optimizing the IOL constants based on refractive outcomes.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Aged 18 years or older;
Patients willing, able, and with sufficient cognitive awareness to comply with examination procedures and schedule for follow-up visits;
Patients with clinically significant age-related cataract (cataract grades of 1, 2, 3 on the LOCSIII scale, but otherwise healthy, requiring surgical treatment, and scheduled for unilateral or bilateral phacoemulsification or Femtosecond-Laser-Assisted cataract surgery;
Patients with existing regular corneal astigmatism of minimum 0.75 D in at least the first eye to be operated.
Disqualifiers
Previous intraocular or corneal surgery in either eye that might confound the outcome of the study or increase the risk to the subject;
Keratometric astigmatism (assessed by IOL Master) of minimum 0.75 D in the first eye
Traumatic cataract;
Pregnancy or lactation;
Trial design
Single group
Treatments tested in this trial
Monofocal toric IOL
DeviceThe device under investigation is a CE-approved monofocal bitoric, aspheric, aberration-correcting intraocular lens indicated for aphakia after surgical extraction of the cataractous natural lens and is also indicated for the correction of regular corneal astigmatism.
Treatment groups
Trial outcomes
Primary outcomes
Refractive predictability
Difference between predicted Manifest Refraction Spherical Equivalent and achieved Manifest Refraction Spherical Equivalent at the final postoperative visit: Percentage of first implanted eyes within ± 1.0 D
Secondary outcomes
Refractive outcomes
Manifest Refraction: Sphere, Cylinder, Manifest Refraction Spherical Equivalent
Refractive predictability
Percentage of eyes within ± 0.25 D, ± 0.5 D, \& ± 1.0 D
Reduction in cylindrical power
The change in manifest refractive cylinder from baseline to the final postoperative visit.
IOL Rotation
Percentage of IOLs with IOL rotation with less than 10 and 20 degrees.
Other outcomes
Preservation of Corrected Distance Visual Acuity
Rate of eyes with postoperative CDVA 0.3 logMAR or better
Contrast Sensitivity
Posterior Capsule Opacification
Rate of occurrence and grading
Rate of performed and planned Nd:YAG laser capsulotomies
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Carl Zeiss Meditec AG
Lead sponsor
targomedGmbH
Collaborator