Post-market Clinical Follow-up Data Collection From Procedures With BIOTRONIK EP Products

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorBiotronik SE & Co. KG

About this trial

This data collection is designed to provide evidence for the safety, performance, and clinical benefit of BIOTRONIK's EP products. Additionally, residual risks will be monitored and newly emerging risks identified.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Indication for diagnostic or therapeutic EP intervention

BIOTRONIK catheter (AlCath, ViaCath, MultiCath, Khelix)

BIOTRONIK external device (Qubic Stim, Qubic RF, Qiona)

BIOTRONIK transseptal sheath (Senovo Bi-Flex)

Disqualifiers

Age less than 18 years

Pregnant or breastfeeding

Prior participation in this study with performed EP procedure

Participation in an interventional clinical investigation in parallel to the BIO|COLLECT.EP study

Trial population

Patients indicated for diagnosis and treatment of intracardiac arrhythmias in an EP lab environment.

Trial design

Design model

Other

Time perspective

Prospective

Treatments tested in this trial

  • BIOTRONIK EP catheters (AlCath, MultiCath, ViaCath), external devices (Qubic RF, Qubic Stim, Qiona) and transseptal sheaths (Senovo bi-flex)

    Device

    Ablations and diagnostic catheters are indicated for temporary transvenous application in patients with cardiac arrhythmias during electrophysiology study (EPS) or catheter ablation interventions. They will be used in combination with external devices like RF generators, external pacemakers cardiac stimulators and / or irrigation pumps.

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Rate of Device deficiencies

Device deficiencies for each investigational device type that occur during the EP procedures in patients, users or other persons

Time frame
During EP procedure
2

Rate of Peri-procedural adverse device effects for each investigational device type

Peri-procedural adverse device effects for each investigational device type that occur in all patients until or at the 24-hour follow-up

Time frame
Until or at 24-hour follow-up
3

Rate of Post-procedural adverse device effects

Post-procedural adverse device effects that occur in the AlCath group after the 24-hour follow-up until or at the 3- to 6-month follow-up

Time frame
After the 24-hour follow-up until or at the 3- to 6-month follow-up
4

Percentage of Clinical benefit confirmations per number of use cases

Clinical benefit at the time of procedure for each investigational device type

Time frame
At the time of procedure

Secondary outcomes

Other outcomes

1

Procedure setting (related to used BIOTRONIK EP products and competitor products)

Type of procedure, type of catheter models, recording system, RF ablation generator, irrigation pump, stimulator, 3D system, patient cable

Time frame
Intervention
2

Procedural parameters

Fluoroscopy time, Procedure duration, duration of RF energy delivery, date and time of procedure

Time frame
Intervention
3

Patient details

demographics, medical history, and concomitant cardiovascular medication

Time frame
Baseline
4

Device performance

e.g., successful insertion and advancing of catheter, successful stimulation and recording of intracardiac signals, RF energy application, removal, replacement/substitution of catheter, device used within its intended purpose

Time frame
Intervention

Sponsors and contacts

Click on the lead sponsor to view all of their trials.