The goal of this observational study is to learn which toric lens calculator best predicts the astigmatism remaining after cataract surgery in adults who received a TECNIS DIU toric intraocular lens (IOL) at Klinik Hietzing, Vienna, between January 2023 and March 2026.
Toric lenses correct astigmatism (an uneven curvature of the cornea) during cataract surgery. The strength of the lens and its orientation in the eye are chosen with online calculators. In an earlier study of the same patients, two widely used calculators - the Johnson \& Johnson toric calculator and the Barrett calculator of the European Society of Cataract and Refractive Surgeons (ESCRS) - recommended different lenses in about 6 out of 10 eyes. It is not known which recommendation leads to the better result.
The main questions it aims to answer are:
1. In eyes in which the two calculators disagreed, which calculator predicted the astigmatism after surgery more accurately? 2. How accurate are four further calculator options, and did the toric lenses stay in their planned position?
Researchers will compare the astigmatism that each calculator predicted for the lens that was actually implanted with the astigmatism measured after surgery.
Participants will:
1. Attend one examination visit of about 60 to 90 minutes, at least 3 months after their cataract surgery 2. Have standard eye examinations: a vision test, a test for glasses (refraction), and several painless optical scans that do not touch the eye 3. Have the eye examined at the slit lamp; drops to widen the pupil are given only at the end of the visit, if needed, to check the position of the lens
No treatment, medication or surgery is given as part of this study.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Participation in the retrospective toric IOL calculator comparison study at Klinik Hietzing (MA15-EK 26-035-VK), with Study ID assigned and complete archived preoperative dataset and calculator outputs for all six calculator pathways
Cataract surgery with implantation of a toric IOL of the TECNIS DIU platform at Klinik Hietzing between January 2023 and March 2026
Documented implantation parameters (implanted DIU model and step, intended implantation axis) available from the operative record
At least 3 months between cataract surgery and the outcome visit
Disqualifiers
Ocular surgery or procedures on the study eye after cataract surgery that may affect refraction, corneal parameters or IOL position (e.g., corneal refractive surgery, IOL exchange, IOL repositioning or rotation, any intraocular surgery); uncomplicated Nd:YAG capsulotomy without IOL repositioning is not an exclusion criterion
Implanted IOL not of the TECNIS DIU toric platform
Documented intraoperative complication with confirmed or suspected IOL malposition (posterior capsule rupture with vitreous loss, zonular dialysis requiring a capsular tension ring, sulcus placement, or any other deviation from in-the-bag placement)
Acute ocular pathology at the outcome visit that prevents reliable refraction or biometry (e.g., corneal edema, active anterior uveitis, dense vitreous hemorrhage)
Trial population
Adult patients who underwent cataract surgery with implantation of a TECNIS DIU toric IOL at the Department of Ophthalmology, Klinik Hietzing, Vienna, Austria, between January 2023 and March 2026, and who form the source cohort (128 patients, 182 eyes) of the retrospective toric IOL calculator comparison study (MA15-EK 26-035-VK). All members of the cohort are invited in writing to a single outcome visit.
Trial design
Cohort
Cross-sectional
Treatments tested in this trial
Standardized Postoperative Outcome Visit
Other interventionSingle non-invasive examination visit (approximately 60-90 minutes), at least 3 months after cataract surgery, in a fixed sequence: uncorrected distance visual acuity, ray-tracing wavefront aberrometry (iTrace), optical biometry (IOLMaster 700), anterior segment OCT tomography (CASIA2), Scheimpflug tomography (Pentacam AXL), autorefraction and standardized manifest refraction with best-corrected distance visual acuity, and slit-lamp examination with posterior capsule opacification grading, toric IOL axis documentation by retroillumination and assessment of centration and tilt. Pupil dilation only after completion of all pupil-dependent measurements. No study-related treatment, medication or surgery.
Toric IOL Calculator Pathways (Exposure)
Other interventionArchived preoperative toric planning outputs of six calculator pathways, generated from a standardized input set in the preceding retrospective study: Johnson \& Johnson toric calculator with posterior corneal astigmatism correction enabled (PCA-ON) and disabled (PCA-OFF), and the ESCRS toric calculator with the Barrett, Kane, EVO 2.0 and Hoffer QST engines. The residual astigmatism predicted for the actually implanted toric step is compared with the measured postoperative outcome. No treatment is assigned within this study; all lenses were implanted during routine care.
Treatment groups
Trial outcomes
Primary outcomes
Paired Difference in Alpins Difference Vector Magnitude Between the J&J Toric Calculator (PCA-ON) and ESCRS-Barrett in Eyes With Clinically Relevant Planning Discrepancy
For each eye, the difference vector (DV) is the vector difference (J0/J45 power-vector space) between the residual astigmatism predicted by a calculator for the actually implanted TECNIS DIU toric step and the residual refractive astigmatism measured by standardized manifest refraction (plus-cylinder notation). The paired difference is \|DV J\&J PCA-ON\| minus \|DV Barrett\| (diopters); negative values favor J\&J, positive values favor Barrett. Population: eyes with clinically relevant planning discrepancy (ClinRel = 1: toric step difference ≥1 and/or axis difference ≥10° between the two calculators), one eye per patient. Primary result: mean paired difference with two-sided 95% confidence interval, interpreted against a pre-specified zone of practical equivalence of ±0.125 D; stratified by astigmatism phenotype (with-the-rule, against-the-rule, oblique).
Secondary outcomes
Prediction Accuracy of Six Toric Calculator Pathways (Difference Vector Magnitude)
Magnitude of the Alpins difference vector (D) between the residual astigmatism predicted for the implanted toric step and the manifest refractive astigmatism, for J\&J PCA-ON, J\&J PCA-OFF, ESCRS-Barrett, ESCRS-Kane, ESCRS-EVO 2.0 and ESCRS-Hoffer QST; mean ± SD and median \[IQR\]; pairwise within-eye comparisons of all 15 pathway pairs (Friedman test, Holm-corrected Wilcoxon signed-rank tests); full cohort and by ClinRel status and astigmatism phenotype. Alpins magnitude of error, angle of error and correction index are reported once per eye.
Proportion of Eyes With Difference Vector Magnitude ≤0.50 D and ≤0.25 D per Calculator Pathway
Percentage of eyes with an Alpins difference vector magnitude ≤0.50 D and ≤0.25 D for each of the six calculator pathways, with Wilson 95% confidence intervals; pairwise comparisons between pathways with McNemar tests.
Residual Refractive Astigmatism in J&J-Concordant Versus Barrett-Concordant Eyes (ClinRel = 1)
Manifest refractive cylinder (D) in ClinRel = 1 eyes in which the implanted toric step matched the J\&J PCA-ON recommendation versus eyes in which it matched the Barrett recommendation; Mann-Whitney U test and linear regression adjusted for anterior and posterior corneal astigmatism, astigmatism phenotype, IOL misalignment, posterior capsule opacification grade and time since surgery. Formal comparison only if each group contains ≥10 eyes.
Postoperative Residual Refractive Astigmatism
Manifest refractive cylinder (D, plus-cylinder notation), axis (degrees) and J0/J45 vector components; proportions of eyes with ≤0.50 D, ≤0.75 D and ≤1.00 D; full cohort and ClinRel = 1 versus ClinRel = 0 eyes (unadjusted and confounder-adjusted).