Safety and Clinical Performance of the Next-Generation SAFESYNC Transcatheter Heart Valve in Patients With Severe Aortic Stenosis

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorBraile Biomedica Ind. Com. e Repr. Ltda.

About this trial

The objective of this pivotal, prospective, multicenter, single-arm clinical trial is to evaluate the safety and clinical performance of the Next-Generation INOVARE® SAFESYNC Bioprosthetic Heart Valve, implanted via a transcatheter approach, in patients with severe aortic stenosis, an indication for TAVI, and intermediate or higher surgical risk. The study will enroll 40 participants.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Severe aortic valve stenosis diagnosed according to criteria established in current guidelines.

Intermediate or higher surgical risk, defined as a Society of Thoracic Surgeons (STS) score ≥4%.

Indication for transcatheter aortic valve implantation (TAVI).

Willing and able to participate in the study and provide written informed consent.

Disqualifiers

Any condition considered a contraindication to implantation of a bioprosthetic heart valve (e.g., indication for a mechanical heart valve).

Known hypersensitivity or contraindication to aspirin, clopidogrel, heparin, nitinol (titanium or nickel), or contrast media that cannot be adequately managed with premedication. This includes heparin-induced thrombocytopenia (HIT) or heparin-induced thrombocytopenia with thrombosis (HITTS).

Blood dyscrasias, including leukopenia (white blood cell count <1,000/mm³), thrombocytopenia (platelet count <100,000 cells/mm³), history of coagulopathy, or hypercoagulable states.

Active infection, including endocarditis.

Trial design

Design model

Single group

Treatments tested in this trial

  • INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve

    Device

    Participants will undergo TAVI via transfemoral access using the INOVARE® SAFESYNC Next-Generation Bioprosthetic Heart Valve and the B-Delivery System.

Treatment groups

40 Participants
are divided into 1 treatment group
Group A: INOVARE® SAFESYNC Next-Generation TAVIExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Device Success According to VARC-3 Criteria

Technical success; Absence of mortality; Absence of surgery or intervention related to the device or to major vascular, access-related, or cardiac structural complications; Intended valve performance, defined as mean transvalvular gradient \<20 mmHg, peak velocity \<3 m/s, Doppler velocity index ≥0.25, and less than moderate aortic regurgitation.

Time frame
30 days after the procedure

Secondary outcomes

1

Percentage of Participants Achieving Technical Success According to VARC-3 Criteria

Defined as freedom from mortality; successful vascular access, delivery of the device, and retrieval of the delivery system; correct positioning of a single prosthetic heart valve in the intended anatomical location; and freedom from surgery or intervention related to the device or to a major vascular, access-related, or cardiac structural complication. Results will be reported as the number and percentage of participants achieving technical success.

Time frame
During the procedure
2

Incidence and Severity of Paravalvular Leak

Paravalvular leak will be assessed by transthoracic echocardiography and classified according to severity. The number and percentage of participants with paravalvular leak in each severity category will be reported.

Time frame
30 days, 6 months, 12 months, and annually through 5 years
3

Mean Transvalvular Aortic Pressure Gradient Assessed

Mean transvalvular aortic pressure gradient will be assessed by transthoracic echocardiography and reported in mmHg.

Time frame
30 days, 6 months, 12 months, and annually through 5 years
4

Distribution of Participants by New York Heart Association Functional Class

Functional status will be assessed using the New York Heart Association (NYHA) Functional Classification. The classification ranges from Class I to Class IV, where Class I represents no limitation of physical activity and Class IV represents inability to perform physical activity without symptoms and/or symptoms at rest. Higher NYHA classes indicate worse functional status. Results will be reported as the number and percentage of participants in each NYHA functional class.

Time frame
30 days, 6 months, 12 months, and annually through 5 years

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: