About this trial
UCon is a medical device for treatment of the symptoms of overactive bladder (OAB) and bowel dysfunction (BD). It electrically stimulates the DGN through the skin to obtain modulated behaviour of the bladder/bowel musculature e.g., suppress undesired bladder/bowel activity to relieve the symptoms of the patient.
This clinical investigation is designed as a single-arm, prospective, multi-centre, and early feasibility study.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Participant is female
Participant is ≥ 18 years of age.
Participant is diagnosed with OAB or BD.
Participant is able to communicate, provide feedback, understand and follow instructions during the course of the investigation, including using the device at home.
Disqualifiers
Participant is medically unstable (acute illness or complication of a chronic condition, apart from the OAB or BD, that might affect the participants´ participation in the investigation).
Participant has an active infection in the genital area.
Participant has an implanted pacemaker, implantable drug pump or other active medical devices (any medical device that uses electrical energy or other sources of power to make it function).
Participant is pregnant, nursing or planning a pregnancy (to be confirmed with a negative pregnancy test). Women of childbearing potential must maintain effective contraception during the clinical investigation.
Trial design
Single group
Treatments tested in this trial
UCon-Bar
DeviceThe participant self-administer electrical stimulation to the dorsal genital nerve (DGN) for either 4 weeks or 12 weeks using UCon with the Bar electrode
Treatment groups
Trial outcomes
Primary outcomes
PRIMARY SAFETY: ratio of participants with successful insertion of the UCon Bar Electrode.
1\) Number and severity of adverse events during insertion of the UCon Bar Electrode: Excessive pain and excessive bleeding. 2) Number and severity of adverse events after insertion: Infection, pain, and bleeding. 3) Number of participants with successful insertion with no premature removal of the Bar Electrode.
PRIMARY PERFORMANCE: ratio of treatment change [performance] of OAB/BD symptoms
Ratio of participants with at least 50% reduction of their OAB/BD symptoms from baseline as assessed by subjective reporting in an electronic bladder or bowel diary.
Secondary outcomes
SECONDARY SAFETY: Characterization, including frequency and severity of adverse events related to the risks and anticipated adverse device effects associated with the use of UCon-Bar Electrode.
1\) Characterization of adverse events and adverse device effects associated with the use of UCon-Bar during the investigational period.2) Number of participants experiencing adverse events and adverse device effects associated with the use of UCon-Bar during the investigational period.3) Number and severity of adverse events and adverse device effects associated with the use of UCon-Bar during the investigational period.
SECONDARY PERFORMANCE: ratio of treatment change [performance] of OAB/BD symptoms
Ratio of participants with at least 33% reduction of their OAB/BD symptoms from baseline as assessed by subjective reporting in an electronic bladder or bowel diary.
SECONDARY PERFORMANCE: assess whether participants using UCon Bar Electrode experience a change in their quality of life
Ratio of subjects with a change in their self-reported quality of life measures as assessed by specific QoL questionnaires related to OAB (ICIQ-OAB, an overall score with greater values indicates increased symptom severity) or BD (St. Marks incontinence score and Rockwood Fecal Incontinence Quality of Life Scale, an overall score with greater values indicates a worse symptom outcome.)
SECONDARY PERFORMANCE: assess whether participants using UCon Bar Electrode experience an impression of treatment improvement
Ratio of participants with a self-reported improvement in their impression of treatment as assessed by the 7-point Patient Global Impression of Improvement (PGI-I) scale. An improvement is defined as choosing one of the following: very much, better, much better, or a little better.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
InnoCon Medical
Lead sponsor
Aarhus University Hospital
Collaborator
Odense University Hospital
Collaborator
Herlev Hospital
Collaborator