About this trial
The STREAMLINE-PVI trial is a prospective, single-center, randomized, open-label clinical trial comparing pulsed field ablation (PFA) with cryoballoon ablation (Cryo) for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF).
A total of 94 patients undergoing first-time PVI will be randomized 1:1 to either PFA or Cryo within standardized Lean Six Sigma (LSS)-optimized procedural workflows. The primary objective is to evaluate whether PFA reduces total procedure duration by at least 20% compared with Cryo without compromising safety or efficacy.
Secondary outcomes include post-procedural recovery, readiness for same-day discharge, atrial arrhythmia recurrence, AF burden, and procedural complications during a 12-month follow-up period.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥18 years
Willingness to participate and ability to provide informed consent
Atrial fibrillation diagnosed within the past 2 years
Scheduled for first-time pulmonary vein isolation (PVI)
Disqualifiers
Previous catheter ablation for atrial fibrillation
Reversible cause of atrial fibrillation (e.g., thyrotoxicosis, alcohol ingestion)
Coexisting non-pulmonary vein-dependent atrial tachycardia
Heart failure with reduced ejection fraction (LVEF ≤40%)
Trial design
Parallel
Treatments tested in this trial
Pulsed Field Ablation (PFA)
Procedure/SurgeryPulmonary vein isolation using the Medtronic PulseSelect system under conscious sedation.
Cryoballoon Ablation (Cryo)
Procedure/SurgeryPulmonary vein isolation using the Medtronic Arctic Front Advance system under conscious sedation.
Treatment groups
Trial outcomes
Primary outcomes
Total Procedure Duration
otal procedure duration, defined as the time from first vascular puncture to application of the venous compression bandage, measured in minutes.
Secondary outcomes
Time to Post-Anesthetic Recovery
Time from application of the venous compression bandage to achievement of a Post-Anesthetic Recovery Score of ≥9 points, measured in minutes.
Post-Anesthetic Recovery Score at 1 Hour
Post-Anesthetic Recovery Score assessed one hour after application of the venous compression bandage (range 0-10, higher scores indicating better recovery).
Time to Same-Day Discharge Readiness
Time from application of the venous compression bandage to achievement of a Same-Day Readiness Score (SDRS) ≥8 points, indicating readiness for safe mobilization and discharge.
Atrial Fibrillation/Atrial Tachycardia Burden
Atrial fibrillation and atrial tachycardia burden assessed by rhythm monitoring during the 12-month follow-up period.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.